Specifications

63
OBJECT MAP
7
*1 Since 2byte data is sent and received for Polling I/O message communication, the lowest byte is 0x00.
Produced Connection Path and Consumed Connection Path specifies Application Object of sent and received data. The
format is below.
9 Get/Set
Expected Packet Rate
(EPR)
0 to 0xFFFF
(Example) 2500: 2500ms
12 Get/Set Watchdog Action
0
Transition to time out (initial value)
1
Auto Delete
2
Auto reset
13 Get
Produced Connection
Path Length
0 to 0xFFFF
Specifies the number of bytes of information within the
produced_connection_path attriburte
14 Get
Produced Connection
Path
00 to 0xFF
The value specifies Application Object of sent data. *1
0x62, 0x34, 0x36: Assmbly Instance 70
0x62, 0x34, 0x37: Assmbly Instance 71
0x62, 0x42, 0x30: Assembly Instance 176
15 Get
Consumed Connection
Path Length
0 to 0xFFFF
Specifies the number of bytes of information within the
consumed_connection_path attriburte
3: 3 byte
16 Get
Consumed Connection
Path
00 to 0xFF
The value specifies Application Object of received data.
*1
0x62, 0x31, 0x34: Assmbly Instance 20
0x62, 0x31, 0x35: Assmbly Instance 21
0x62, 0x37, 0x45: Assmbly Instance 126
Class 0x05 Instance 2
Attribute ID Access Name Range Definition
0x62 0xMM 0xNN
Logic address Application Object data