Specifications

72
OBJECT MAP
Class 0x2A Instance 1
Attribute
ID
Access Range Description
101 Set Any
Inverter reset
Set a value other than "0" in Pr. 340 to start in network operation mode after
reset. (Refer to page 26)
*1
102 Set 0x965A Parameter clear *1
103 Set 0x99AA All parameter clear *1
105 Set 0x5A96 Clear parameters *1
Communication parameters are not cleared. *3
106 Set 0xAA99 All parameter clear
*1
112 Get/Set
0 to
0x9C40
Set frequency (RAM) *2
Either write the set frequency to RAM or read
from RAM. (0.01Hz increments)
113 Set
0 to
0x9C40
Set frequency (EEPROM)
*2
Write the set frequency to EEPROM
(0.01Hz increments)
*1 Error response is returned when the inverter will not accept the order.
*2 The data written to Attribute 112, 113 can be read from Attribute 112.
*3 The FR-A7ND E kit parameters (Pr.345, Pr.346) will be cleared on the FR-E700 series manufactured in or before
January 2009.