Specifications

73
OBJECT MAP
7
* Writing any value will clear the alarm definition.
114 Get/Set Inverter status monitor/run command (Refer to page 74)
120 Get/Set
0 External operation
Operation mode read (Get)
1 PU operation
2 External jog operation
3 PU jog operation
4 Network operation
5 External/PU combined operation
0x0010 External operation
Operation mode write (Set)
Input 2 byte data.
0x0011 PU operation (when Pr. 79 = 6)
0x0014 Network operation
141 Get/Set
Alarm definition (latest
alarm
)
Alarm definition all clear
*
Refer to page 77 for alarm
description.
142 Get Alarm definition 2 (second alarm in past)
143 Get Alarm definition 3 (third alarm in past)
144 Get Alarm definition 4 (fourth alarm in past)
145 Get Alarm definition 5 (fifth alarm in past)
146 Get Alarm definition 6 (sixth alarm in past)
147 Get Alarm definition 7 (seventh alarm in past)
148 Get Alarm definition 8 (eigth alarm in past)
Class 0x2A Instance 1
Attribute
ID
Access Range Description