Specifications

75
OBJECT MAP
7
zRun command (Set)
Bit Signal Description
0 (Not used) (Always 0)
1 Forward rotation command
*2
0 : Stop command
1 : Forward rotation start
A starting command is input to the
inverter when the signal turns on.
A stop command is given when both
signals turn on simultaneously.
2 Reverse rotation command
*2
0 : Stop command
1 : Reverse rotation start
3
High speed operation command
(terminal RH function)
*1
Functions assigned to terminal RH, RM and RL are activated.4
Middle speed operation command
(terminal RM function)
*1
5
Low speed operation command
(terminal RL function)
*1
6 (Not used) (Always 0)
7
Second function selection
(RT signal)
*3
1 : Second function is selected.
8
Terminal 4 input selection
(AU signal)
*3
1 : Terminal 4 input is the main speed.
9 (Not used) (Always 0)
10
Output stop
(terminal MRS function)
*1
Functions assigned to terminal MRS are activated.
11 (Not used) (Always 0)
12 Reset (terminal RES function)
*1 Functions assigned to terminal RES are activated.
13 to 15 (Not used) (Always 0)