6.5.3 Set frequency write destination selection (network input SNVT_switch nviInvSetFreqSw)..........................55
6.5.4 Set frequency (0.1Hz increments) (network input SNVT_freq_hz nviInvSetFreq) .......................................56
6.5.5 Set frequency (0.005% increments) (network input SNVT_lev_percent nviInvSetFreqP)............................56
6.5.6 Output frequency monitor (0.1Hz increments) (network output SNVT_freq_hz nvoInvOutFreq) .................57
6.5.7 Output frequency monitor (0.005% increments) (network output SNVT_lev_percent nvoInvOutFreqP) .....58
6.5.8 Output current monitor (0.1A increments) (network output SNVT_amp nvoDrvCurnt) ................................59
6.5.9 Output voltage monitor (0.1V increments) (network output SNVT_volt nvoDrvVolt) ....................................59
6.5.10 Actual operation time monitor (1h increments) (network output SNVT_time_hour nvoDrvRunHours).........59
6.5.11 Cumulative power monitor (1kWh increments) (network output SNVT_elec_kwh nvoDrvRunPower).........60
6.5.12 Cumulative power monitor 2 (0.1kWh increments)
(network output SNVT_elec_kwh_l nvoDrvRunPower_l) .............................................................................61
6.5.13 Alarm reset (network input SNVT_switch nviInvAlarmReset).......................................................................61
6.5.14 Alarm occurrence definition (network output SNVT_str_asc nvoInvAlarmStr) ............................................. 62
6.5.15 Product information (maker name, type) (network output SNVT_str_asc nvoInvTypeInfo) .........................64
6.5.16 Emergency stop command (network input SNVT_hvac_emerg nviEmergOverride)....................................65
6.5.17 Emergency stop status (network output SNVT_hvac_emerg nvoEmergStatus) ..........................................66
6.5.18 Alarm status (network output SNVT_switch nvoDrvAlarm) .......................................................................... 67
6.6 Inverter PID Control Functions.......................................................................................................68
6.6.1 PID set point (network input SNVT_lev_percent nviInvPIDTarget) .............................................................. 69
6.6.2 PID measured value (network input SNVT_lev_percent nviInvPIDValue) ...................................................70
6.6.3 PID deviation (network input SNVT_lev_percent nviInvPIDDev) .................................................................71
6.7 Inverter Extended Functions ..........................................................................................................72
6.7.1 Monitor code (network input SNVT_count nviInvMonCode)......................................................................... 72
6.7.2 Monitor data (network output SNVT_count nvoInvMonData) .......................................................................75
6.7.3 Set frequency (0.01Hz increments) (network input SNVT_count nviInvSetFreq2).......................................76
6.7.4 Output frequency monitor (0.01Hz increments) (network output SNVT_count nvoInvOutFreq2) ................76
6.7.5 Command request (network input SNVT_str_asc nviInvCmdReq) ..............................................................77
6.7.6 Command reply (network output SNVT_str_asc nvoInvCmdReply).............................................................82
6.8 Configuration Properties.................................................................................................................83
6.8.1 Initial communication delay time (network input config SNVT_time_sec nciPwUpOutTm) ..........................83