Instruction manual

80
NETWORK VARIABLES
*1 Communication parameters (Pr. 117 to Pr. 124, Pr. 338 to Pr.340, Pr.343, Pr.349, Pr.549 to Pr.551) are also cleared.
*2 Setting can be made when the link parameter expansion setting = "1, 9".
*3 C22 to C25 are available with the Japanese version only. Refer to the parameter list of the inverter for instruction code.
*4 Gain frequencies can be written using Pr. 125 (instruction code H99) and Pr. 126 (instruction code H9A) also.
All parameter clear Write H00FC
All parameters return to the initial values.
Any of four different all clear operations are performed according to the
data.
Inverter reset Write H00FD H9696: Reset the inverter.
Link parameter
expansion setting
Read H007F
Parameter description is changed according to the H00 to H09 setting.
Refer to the instruction code of the inverter manual for details of the values.
Write H00FF
Second parameter
changing
*2
Read H006C
When setting the bias / gain (C2 to C7, C22 to C25
*3) parameters
H00: Frequency
*4
H01: Analog value set in parameters
H02: Analog value input from the terminal
Write H00EC
Item
Read/
Write
Instruction
Code
Data Description
All clear types ({...Clear, ×...not clear)
Data
Communication
Parameters
Calibration
Parameters
Other
Parameters
HEC, HF3,
HFF
H9696 {
*1
×
{{
H9966 {
*1 {{{
H5A5A
××
{{
H55AA
×
{{{