Instruction manual

82
NETWORK VARIABLES
6.7.6 Command reply (network output SNVT_str_asc nvoInvCmdReply)
Gives a reply to the command requested in "command request (nviInvCmdReq)" (Refer to page 77). The
data entered are the reply code and read data as the command processing results.
The format is as shown below. The data to be set are in ASCII code. The initial setting of +0 to +30 is 0.
Data send event ................... At command processing completion
Refer to page 81 for the command processing procedure.
Reply flag H01 Reply to command request
Reply code
(Results in response
to the command
request enter)
H0000
Normal completion of command
Other than
H0000
Command execution error
H0001: Mode error (different operation mode)
H0002: Instruction code error (specified instruction code does not exist)
H0003: Data range error (data written is outside the range)
Reply data The data is set at reading. (A given value is set at writing.)
Data (ASCII code)
Request flag
Reply code
Reply data
+0
+2
+6
+10 to +30
H
H
L
L
L
0
Storage position
Data (ASCII code)
+0
+2
+6
+10 to +30
H
H
H
L
L
L
0
0
1
0
0
3
2
0
0
0
0
(H30)
(H31)
(H30)
(H30)
(H30)
(H30)
(H30)
(H30)
(H33)
(H32)
1.
When Pr. 8 Deceleration time
with "5.0s" set in is read
Data (ASCII code)
+0
+2
+6
+10 to +30
H
H
H
L
L
L
0
0
1
0
0
A
1
0
1
0
0
(H30)
(H31)
(H30)
(H30)
(H30)
(H30)
(H31)
(H30)
(H41)
(H31)
2.
When the latest alarm (OP1)
and second alarm in past
(OC1) are read
H
Setting example