NETWORK VARIABLES
6.8.3 % set reference frequency (network input config SNVT_freq_hz
nciInvSetFreqBas)
You can set the reference frequency of "set frequency (nviInvSetFreqP)" (Refer to page 56) and "output
frequency monitor (nvoInvOutFreqP)" (Refer to page 58).
The % set reference frequency can not be set at less than the minimum frequency resolution of the
inverter.
* 60Hz for the Japanese and NA version and 50Hz for the EC and CH version.
Data acceptance timing........... At network variable receive (nv_update_occurs event)
Data Name Initial Value Range Increments
nciInvSetFreqBas
60Hz / 50Hz *
1.0Hz to 400.0Hz 0.1Hz/bit
Parameter Name
1.00Hz to 400.00Hz 0.01Hz
390 % setting reference frequency
0.00Hz
(0%)
100.00%
Set frequency (nvilnvSetFreqP)
Output frequency monitor (nvilnvOutFreqP)
Frequency written to inverter
Output frequency of inverter
% setting reference frequency (nciInvSetFreqBas)