Specifications

17
MITSUBISHI ELECTRIC
FR-E 500 EC
Function Parameter Meaning Setting range Default setting
Operation
settings
60
Shortest acceleration/deceleretion mode
0/1/2/11/12 0
61
Reference current
0–500 A / 9999 9999
62
Current limit for intelligent mode (acceleration)
0–200 % / 9999 9999
63
Current limit for intelligent mode (deceleration)
0–200 % / 9999 9999
65
Retry selection
0/1/2/3 0
66
Starting frequency for stall prevention at boost
frequency
0–400 Hz 50 Hz
67
Number of restart retries
0–10 / 101–110 0
68
Waiting time for automatic restart retry
0.1–360 s 1 s
69
Retry count display erasure
00
70
Special regenerative brake duty
0–30 % 0 %
71
Motor selection
0/1/3/5/6/13/15/16/
100/101/103/105/106/113/115/116
0
72
PWM function
0–15 1
73
Specification of setting value input data
0/1/10/11
1
74
Setting value signal filter
0–8 1
75
Reset condition / connection error / stop
0–3 / 14–17 14
77
Write protection for parameters
0/1/2 0
78
Prevention of reverse rotation
0/1/2 0
79
Operation mode selection
0–4 / 6–8 0
Motor
constants
80
Rated motor capacity for flux vector control
0.2–7.5 kW / 9999 9999
82
Motor excitation current
0–500 A / 9999 9999
83
Rated voltage of motor for auto-tuning
0–1000 V 200 V / 400 V
84
Rated motor frequency
50–120 Hz 50 Hz
90
Motor constant A
0–50 / 9999 9999
96
Auto-tuning setting/status
0/1 0
Communications
parameter
117
Station number
0–31 0
118
Communication speed
48 / 96 / 192 192
119
Stop bit length/data length
0 / 1 / 100 / 101 data length 8
10 / 11 / 110 / data length 7
1
120
Parity check presence/absence
0/1/2 2
121
Number of communication retries
0–10 / 9999 1
122
Communication check time interval
0–999.8 s / 9999 9999
123
Wait time setting
0–150 ms / 9999 9999
124
CR / LF absence/presence selection
0/1/2 1
PID control
128
PID action selection
0/20/21 0
129
PID proportional band
0.1–1000 % / 9999 100 %
130
PID integral time
0.1–3600 s / 9999 1 s
131
Upper limit for actual value
0–100 % / 9999 9999
132
Lower limit for actual value
0–100 % / 9999 9999
133
PID action set point for PU operation
0–100 % 0 %
134
PID differential time
0.01–10.00 s / 9999 9999
Auxiliary
functions
145
Language selection
0–7 1
146
Parameter set by manufacturer. Do not set.
Current
detection
150
Output current detection level
0–200 % 150 %
151
Output current detection period
0–10 s 0
152
Zero current detection level
0–200 % 5 %
153
Zero current detection period
0.05–1 s 0.5 s
Sub
functions
156
Stall prevention operation selection
0–31/100 0
158
AM terminal function selection
0/1/2 0
Additional
functions
160
User group read selection
0/1/10/11 0
168
Parameter set by manufacturer. Do not set.
——
169
Initial
monitor
171
Actual operationhour meter clear
00
PARAMETER