Specifications

22
MITSUBISHI ELECTRIC
FR-E 500 EC
Internal and External Options
Option Type Description Remarks / specifications Art. no.
Internal
options
Communi-
cations
boards
Profibus/DP
FR-E5NP
Option board for the integration of a frequency inverter into a
Profibus/DP network. The operation, display functions, and para-
meter settings can be controlled by a computer (PC etc.) or a PLC.
Connection for up to 42 inverters
supported
104556
DeviceNet
TM
FR-E5ND
Option board for the integration of a frequency inverter into a
DeviceNet. The operation, display functions, and parameter settings
can be controlled by a computer (PC etc.) or a PLC.
Maximum transfer rate: 10 MBaud
104557
CC-Link
FR-E5NC
Option board for the integration of frequency inverter into a CC-Link
system. The operation, display functions, and parameter settings
can be controlled by a PLC.
Maximum transfer distance:
1200 m (at 156 x 10 kBaud)
104558
CAN Open
OI-FR-E5NCO
Option board for the integration of a frequency inverter into a
Can-Open network. Operation, indicating functions, and parameter
settings can be controlled via a personal computer or a PLC.
Maximum transfer rate: 1 MBaud
139378
Accessories
PCMCIA communications card
SioCard
Connection between mobile PC (PCMCIA) and frequency inverter
RS485 (RJ45); no external power supply neccessary
Length 3 m; for parametrization and
programming of the frequency inverter;
it can be used for example with the VFD
Setup Software
69946
Conection cable
SC-FR PC
Connection between PC (RS232) and frequency inverte RS485
(RJ45); no external power supply neccessary
88426
A large number of options allows an
individual adoption of the inverter to
the according task. The options can be
installed quickly and easily. Detailed in-
formation on installation and functions
is included in the manual of the options.
The options can be divided into two major
categories:
internal options
external options
Internal options
The internal options comprise communica
-
tions options supporting the operation of
the inverter within a network or connected
to a personal computer or PLC.
SINK
P1
-
+
PR
RH
A
RM
B
RL
C
MRS
10
RES
2
SD
SD
5
AM
4
PC
PC
SD
SE
SE
STF
RUN
STR
FAN
2
FAN
1
FU
SD
SOURCE
SINK
P1
-
+
PR
RH
A
RM
B
RL
C
MRS
10
RES
2
SD
SD
5
AM
4
PC
PC
SD
SE
SE
STF
RUN
STR
FAN
2
FAN
1
FU
SD
SOURCE
D160D9
E.S.D
D160D9
A
FR-E 5ND
SERIAL
SW2
SW3
V-
C-
SH
X10
X1
C+
V+
Mounting examples for an internal option
Installing an
option board
to an FR-E 520S EC
SINK
P1
-
+
PR
RH
A
RM
B
RL
C
MRS
10
RES
2
SD
SD
5
AM
4
PC
PC
SD
SE
SE
STF
RUN
STR
FAN
2
FAN
1
FU
SD
SOURCE
SG (0V)
Bus
termination
SG (0V)
RDA (RX+)
RDB (RX-)
SDA (TX+)
SDB (TX-)
Shield
Frame ground
71611 120 / 250
K76-FR-E5MD
REV: 0
0JFMAMJJ
Installing an
FR-E5MD option board
to an FR-E 520S EC
OPTIONS
D160D9
E.S.D
D160D9
A
FR-E 5ND
SERIAL
SW2
SW3
V-
C-
SH
X10
X1
C+
V+