Instruction manual

15
PARAMETER LIST
156
Stall prevention operation
selection
0 to 31, 100,
101
0
157 OL signal output timer
0 to 25s,
9999
0s
158 AM terminal function selection
1 to 3, 5, 7 to
12, 14, 21,
24, 52, 53,
61, 62
1
160 User group read selection 0, 1, 9999 0
161
Frequency setting/key lock
operation selection
0, 1, 10, 11 0
162
Automatic restart after
instantaneous power failure
selection
0, 1, 10, 11 1
165
Stall prevention operation level
for restart
0 to 200% 150%
168
Parameter for manufacturer setting. Do not set.
169
170 Watt-hour meter clear 0, 10, 9999 9999
171 Operation hour meter clear 0, 9999 9999
172
User group registered display/
batch clear
9999, (0 to
16)
0
173 User group registration
0 to 999,
9999
9999
174 User group clear
0 to 999,
9999
9999
178 STF terminal function selection
0 to 5, 7, 8,
10, 12, 14 to
16, 18, 24,
25, 60, 62,
65 to 67,
9999
60
179
STR terminal function
selection
0 to 5, 7, 8,
10, 12, 14 to
16, 18, 24,
25, 61, 62,
65 to 67,
9999
61
180 RL terminal function selection
0 to 5, 7, 8,
10, 12, 14 to
16, 18, 24,
25, 62, 65 to
67, 9999
0
181 RM terminal function selection 1
182 RH terminal function selection 2
183
MRS terminal function
selection
24
184
RES terminal function
selection
62
Parameter
Name
Setting
Range
Initial
Value
190
RUN terminal function
selection
0, 1, 3, 4, 7,
8, 11 to 16,
20, 25, 26,
46, 47, 64,
90, 91, 93,
95, 96, 98,
99, 100, 101,
103, 104,
107, 108, 111
to 116, 120,
125, 126,
146, 147,
164, 190,
191, 193,
195, 196,
198, 199,
9999
0
191 FU terminal function selection 4
192
A,B,C terminal function
selection
0, 1, 3, 4, 7,
8, 11 to 16,
20, 25, 26,
46, 47, 64,
90, 91, 95,
96, 98, 99,
100, 101,
103, 104,
107, 108, 111
to 116, 120,
125, 126,
146, 147,
164, 190,
191, 195,
196, 198,
199, 9999
99
232 Multi-speed setting (speed 8)
0 to 400Hz,
9999
9999
233 Multi-speed setting (speed 9)
0 to 400Hz,
9999
9999
234 Multi-speed setting (speed 10)
0 to 400Hz,
9999
9999
235 Multi-speed setting (speed 11)
0 to 400Hz,
9999
9999
236 Multi-speed setting (speed 12)
0 to 400Hz,
9999
9999
237 Multi-speed setting (speed 13)
0 to 400Hz,
9999
9999
238 Multi-speed setting (speed 14)
0 to 400Hz,
9999
9999
239 Multi-speed setting (speed 15)
0 to 400Hz,
9999
9999
240 Soft-PWM operation selection 0, 1 1
241
Analog input display unit
switchover
0, 1 0
244 Cooling fan operation selection 0, 1 1
245 Rated slip
0 to 50%,
9999
9999
246
Slip compensation time
constant
0.01 to 10s 0.5s
247
Constant-power range slip
compensation selection
0, 9999 9999
Parameter
Name
Setting
Range
Initial
Value
E700_NA_Guideline_ib0600333ENG.book 15 ページ 2007年11月28日 水曜日 午前10時20分