Instruction manual

13
Connection diagram, encoder cable,
PU connector
INSTALLATION AND WIRING
2
(2) Setting the number of encoder pulses and encoder rotation direction
Set the following parameters according to the encoder specification.
z The rotation direction of the encoder is displayed on the operation status indication (FWD,REV) of the control
panel.
z When using a conventional motor and an encoder cable (FR-VCBL/FR-JCBL), refer to the
Instruction Manual (detailed).
z Encoder output circuit
jumper connector
The jumper connector is fitted to
complimentary when shipped from
the factory. Switch its position
according to output circuit.
Parameter Name Factory Setting Setting Range Remarks
851 Number of encoder pulses 2048 0 to 4096 These parameters are extended
function parameters. Set "1" in
Pr.160 "extended function selection"
852 Encoder rotation direction 1 0, 1
Pr. 852 Setting Rotation direction of the encoder
0
1
(factory setting)
REMARKS
The number of encoder pulses should be between 1000 and 4096.
Complimentary (CMP)
Terminating resistance
Differential line driver (LDV)
Terminating resistance
Forward rotation is clockwise rotation
when viewed from A.
A
Encoder
CW
Forward rotation is counterclockwise rotation
when viewed from A.
CCW
AA
Encoder