Instruction manual

1
OUTLINE
1
1 OUTLINE
All models of general-purpose inverters used by specific consumers are covered by "Harmonic suppression
guideline for consumers who receive high voltage or special high voltage".
(For further details, refer to Instruction Manual (detailed).)
Unpack the inverter and check the capacity plate on the front cover and the rating plate on the inverter side face to
ensure that the product agrees with your order, an accessory L-shaped jumper (Refer to page 15 for connection
method.) is included, and the inverter is intact.
Harmonic Suppression Guideline
Product check and name of parts
(1) Front view
(2) Without front cover
*The 5.5K or less inverter is equipped with a built-in brake resistor and the 15K or less inverter is equipped
with a built-in brake transistor.
Plates
Inverter type Serial number
Capacity plate
Serial number
Rating plate
Inverter type
Input rating
Output rating
Inverter type
FR
-
V520
-K
Inverter
capacity
(kW)
1.5
.
Terminal 5 dedicated L-shaped jumper × 1 (supplied)
Symbol
V520
Three-phase 200V class
Voltage class
V540
Three-phase 400V class
ALARM lamp
Wiring port cover for option
(DATA PORT)
Front cover
POWER lamp
Accessory cover
Rating plate
Brake resistor* (Fitted to the back)
Control panel (FR-DU04-1)
Capacity plate
Control circuit terminal block
Main circuit terminal block
PU connector
(Provided with modular jack
type relay connector)
(For use with RS-485 cable
communication)
Modular jack type relay
connector compartment
Inboard option mounting positions
Wiring cover