Instruction manual

Function list (Extended function parameters)
65
PARAMETERS
PARAMETERS
5
Maintenance
functions
168
Maker setting parameters. Do not set.
169
Initial
monitor
171
Actual operation hour
meter clear
You can clear the actual operation hour meter. 0
{{{
Terminal assignment functions
180
DI1 terminal function
selection
You can select the following input signals.
0: RL (multi-speed low-speed run command) Pr. 180 factory setting
1: RM (multi-speed middle-speed run command) Pr. 181 factory setting
2: RH (multi-speed high-speed run command) Pr. 182 factory setting
3: RT (second function selection) Pr. 183 factory setting
5: JOG (jog operation selection)
8: REX (multi-speed 15 speeds selection)
9: X9 (third function selection)
10: X10 (FR-HC,FR-CV connection (inverter run enable signal))
11: X11 (FR-HC connection (instantaneous power failure detection)
12: X12 (PU operation external interlock)
14: X14 (PID control valid)
15: BRI (brake release completion signal)
16: X16 (PU operation-external operation switchover)
20: X20 (S-pattern acceleration/deceleration C switching terminal)
22: X22 (orientation command)
23: LX (pre-excitation/servo on)
24:MRS(output stop)
25: STOP (start self-holding selection)
26: MC (control mode switching)
27: TL (torque limit selection)
28: X28 (start time tuning)
42: X42 (torque bias selection 1)
43: X43 (torque bias selection 2)
44: X44 (P control selection (P/PI control switching))
9999: No function (STR when set in Pr. 187)
0
{{{
181
DI2 terminal function
selection
1
{{{
182
DI3 terminal function
selection
2
{{{
183
DI4 terminal function
selection
3
{{{
187
STR terminal function
selection
9999
{{{
Terminal assignment functions
190
DO1 terminal function
selection
You can select the followin
g output signals.
0 (positive logic) Pr. 190 factory setting, 100 (negative logic): RUN (inverter running)
1 (positive logic) Pr. 191 factory setting, 101 (negative logic): SU (up to speed)
2 (positive logic) Pr. 192 factory setting, 102 (negative logic): IPF (instantaneous
power failure or undervoltage)
3 (positive logic), 103 (negative logic) : OL (overload warning)
4 (positive logic), 104 (negative logic) : FU (output speed detection)
5 (positive logic), 105 (negative logic) : FU2 (second output speed detection)
6 (positive logic), 106 (negative logic) : FU3 (third output speed detection)
7 (positive logic), 107 (negative logic) : RBP (regenerative brake prealarm)
8 (positive logic), 108 (negative logic) : THP (
electronic thermal relay function prealarm)
10 (positive logic), 110 (negative logic) : PU (PU operation mode)
11 (positive logic), 111 (negative logic) : RY (inverter operation ready)
12 (positive logic), 112 (negative logic) : Y12 (output current detection)
13 (positive logic), 113 (negative logic) : Y13 (zero current detection)
14 (positive logic), 114 (negative logic) : FDN (PID lower limit)
15 (positive logic), 115 (negative logic) : FUP (PID upper limit)
16 (positive logic), 116 (negative logic) : RL (PID forward/reverse rotation output)
20 (positive logic), 120 (negative logic) : BOF (brake opening request)
25 (positive logic), 125 (negative logic) : FAN (fan failure output)
26 (positive logic), 126 (negative logic) : FIN (heatsink overheat prealarm)
27 (positive logic), 127 (negative logic) : ORA (orientation completion)
30 (positive logic), 130 (negative logic) : Y30 (forward rotation output)
31 (positive logic), 131 (negative logic) : Y31 (reverse rotation output)
32 (positive logic), 132 (negative logic) : Y32 (regenerative status output)
33 (positive logic), 133 (negative logic) : RY2 (operation ready 2)
34 (positive logic), 134 (negative logic) : LS (low speed output)
35 (positive logic), 135 (negative logic) : TU (torque detection)
36 (positive logic), 136 (negative logic) : Y36 (in-position)
37 (positive logic), 137 (negative logic) : MT (maintenance timer output)
39 (positive logic), 139 (negative logic) : Y39 (start time tuning completion)
40 (positive logic), 140 (negative logic) : Y40:(trace status)
41 (positive logic), 141 (negative logic) : FB (speed detection)
42 (positive logic), 142 (negative logic) : FB2 (second speed detection)
43 (positive logic), 143 (negative logic) : FB3 (third speed detection)
44 (positive logic), 144 (negative logic) : RUN2 (second inveter operating)
96 (positive logic), 196 (negative logic) : REM (remote output)
97 (positive logic), 197 (negative logic) : ER (minor fault output 2)
98 (positive logic), 198 (negative logic) : LF (minor fault output)
99 (positive logic) Pr. 195 factory setting, 199 (negative logic): ABC (alarm output)
9999: No function
0
{{{
191
DO2 terminal function
selection
1
{{{
192
DO3 terminal function
selection
2
{{{
195
A,B,C terminal
function selection
99
{{{
Function
Parameter
Name Outline
Factory
Setting
Cus-
tomer
Set-
ting
At-a-glance Guide to
Functions
{: Usable function
×: Unusable function
* :
Functions that can be used
for parameter-set position
control
Vector Control
Speed
control
Torque
control
Position
control