Installation manual

English
NA - 12
Test Run
Step What to check for Check
1
Check the power supply
voltage
Is the proper power being used?
(JT-MC106G-W-NA type: Input Power: 120 Vac Single-phase )
Incorrect power supply may cause malfunctions or low
wind power.
2
Turn the ground fault circuit
interrupter on.
3
Turn the sensor switch is "ON".
(page 4)
Are any lights in the display on?
4
Insert your hands to check if air is
being blow. (page 4)
Is the air blowing?
5
Turn the heater switch "ON".
(page 14)
Is warm air blowing?
( Even if the heater switch is "ON", the heater may not operate if
it is used continually.)
As the heater is a simple heater, the air may not feel so
warm if the room temperature is low (68F (20C) or below).
6
Is the unit mounted securely without any vibration or abnormal
noises?
󱛠 The maintenance light and heater light turn off after about 10 seconds. When the sensor switch or heater switch are
pressed again, the lights in the display section turn back on in the state where the settings have been made.
Caution
󱛠 If the po
wer light flashes, turn the breaker "OFF", check that power light is off, and then wait for 1 minute before
switching the breaker back "ON".