ENERGY RECOVERY VENTILATORS MODEL RX5 SERIES Concentrating what we can do. more, ever and definitely... HEAD OFFICE : MITSUBISHI DENKI BLDG., 2-2-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN http://Global.MitsubishiElectric.com Y08-003 Nov.2008(MEE) Specifications subject to change without notice.
Simple and Effective Excellent air quality and unbeatable Heat Exchange Efficiency LOSSNAY's Energy Recovery Technology and Simultaneous Ventilations (Supply and Exhaust) Contribute to Excellent Indoor air Quality and Significantly Reduce the Outdoor air load. Energy-Recovery Concept by Hyper Eco LOSSNAY Core In summer In winter Temperature difference between air supply and room: 1.7 ºC About 4kg/h of water vapor is recovered.
Hyper Eco Core New function: "By-pass" Ventilation External Control Setting Better energy conservation by improved total heat exchange efficiency. In addition to the automatic damper open/close function, open/close control via external devices is now possible, delivering a“By-pass” ventilation system that is suitable to the installed environment. Introducing the new Hyper Eco Element Mitsubishi's newly developed Hyper Eco Element is on board, offering the industry's best total heat exchange efficiency.
Multi-ventilation Mode enables the appropriate supply/ exhaust balance to be selected to suit the usage environment and location Featuring "Multi-ventilation Mode," which allows the air supply/exhaust balance to be varied dynamically. The supply/exhaust balance can be selected to suit the usage environment and location, such as allowing for air exhausted via extractor fans. Modes can be selected easily by setting the connectors on the circuit board.
Control The New Remote Controller PZ-60DR-E enable simple control setting Interlocked with Air conditioners LOSSNAY independent Interlocked with City Multi Interlocked with Mr.Slim M-NET transmission line City Multi Slim-LOSSNAY connection cable LOSSNAY RX5 Mr.Slim Can Be Used With AG-150A Centralized Controller Controllers are one of the most important and familiar devices in an air conditioning system.
List of Remote Controller Settings and Functions Controllers The remote controller provides a wide range of functions and features other than the main functions described above, such as sophisticated energy conservation control and an easy to see, easy to use interface.
A Breath of Freshness in Restaurants, Offices, and Schools Restaurants Offices Schools A restaurant can never be too clean and its air never too fresh Fresh air–improving the overall quality of working life Creating the best possible environment for our children to succeed The atmosphere of a restaurant is crucial to securing customers and making them happy enough to come back for more.
Specifications / Dimensions LGH-15 to 100RX5 LGH-15RX5-E LGH-15RX5-E Model Frequency / Power source 50Hz / Single phase 220-240V Ventilation mode Fan speed Extra High High Low Extra Low Extra High High Low Extra Low Current (A) 0.44-0.46 0.37-0.38 0.25-0.25 0.14-0.15 0.45-0.46 0.37-0.38 0.25-0.26 0.14-0.15 96-110 80-90 53-59 30-35 97-110 81-91 54-61 30-35 (m3/h) 150 150 110 70 150 150 110 70 (L/s) 42 42 31 19 42 42 31 19 (mmH2O) 10.2-10.7 6.6-7.1 3.6-4.
LGH-25RX5-E LGH-35RX5-E LGH-25RX5-E Model Frequency / Power source LGH-35RX5-E Model Frequency / Power source 50Hz / Single phase 220-240V 50Hz / Single phase 220-240V Ventilation mode Fan speed Extra High High Low Extra Low Extra High High Low Extra Low Ventilation mode Fan speed Extra High High Low Extra Low Extra High High Low Extra Low Current (A) 0.52-0.55 0.47-0.48 0.26-0.27 0.17-0.18 0.53-0.55 0.47-0.48 0.26-0.27 0.17-0.18 Current (A) 0.92-0.92 0.74-0.74 0.5-0.
LGH-50RX5-E LGH-65RX5-E LGH-50RX5-E Frequency / Power source LOSSNAY ventilation By-pass ventilation 50Hz / Single phase 220-240V Ventilation mode Fan speed LOSSNAY ventilation Extra High High Low Extra Low Extra High High Low Extra Low Current (A) 1.2-1.25 1.0-1.0 0.85-0.85 0.4-0.4 1.25-1.25 1.0-1.0 0.85-0.85 0.4-0.
LGH-80RX5-E LGH-100RX5-E LGH-80RX5-E Frequency / Power source 50Hz / Single phase 220-240V Ventilation mode Fan speed Extra High High Low Extra Low Extra High High Low Extra Low Ventilation mode Fan speed Current (A) 1.75-1.75 1.6-1.6 1.45-1.45 0.60-0.65 1.75-1.75 1.6-1.6 1.45-1.45 0.60-0.
LGH-150RX5-E LGH-200RX5-E LGH-150RX5-E LOSSNAY ventilation Power consumption (W) Extra High High Low 3.5-3.5 3.2-3.2 2.9-2.9 3.5-3.5 3.2-3.2 2.9-2.9 Current (A) Power consumption (W) 760-830 690-740 630-680 765-835 695-745 635-685 1500 1500 1300 1500 1500 1300 (L/s) 417 417 361 417 417 361 (mmH2O) 16.3-17.8 13.3-13.8 9.7-10.2 16.3-17.8 13.3-13.8 9.7-10.2 (Pa) 160-175 130-135 95-100 160-175 130-135 95-100 80.0 80.0 81.
Wiring Diagrams LGH-15RX5 to 100RX5 LGH-150RX5 and 200RX5 GREEN/YELLOW BROWN RED BLACK GREY YELLOW M2 TM1 L TAB5 TAB3 BLUE TAB1 CN10 TAB2 N BROWN Isolator BROWN RED N BROWN BLACK GREY YELLOW M2 SUPPLY FAN MOTOR BLUE C TR RED ORANGE BLUE WHITE CN9 C EXHAUST FAN MOTOR M1 YELLOW GM (*2) TAB1 CN10 TAB2 EXHAUST FAN MOTOR RED BROWN BLUE TR1 CN1 x203 ORANGE BLUE x202 WHITE x203 C (*2) PE BLUE x101 x101 RED CN7 x102 x202 RED RED CN9 CN7 x201 LS WHITE RED WHITE BROWN
Sample Installations LGH-15RX5 to 100RX5 LGH-150RX5 and 200RX5 Exhaust air grille A Exhaust grille (user supplied) Suspension bolt position Suspension bolt position Air-supply grille (user supplied) 150 to 250 600 or more Suspension bolt position Inspection opening LOSSNAY core/ air filter/ fan maintenance space 414 Supply air grille Suspension bolt position (ordered by customer) Air-supply grille (user supplied) OA (fresh-air intake) Duct (user supplied) Duct diameter 200 (ordered by custome