3. COOL AIR/VARY Operation
Control Summary
(a) Dehumidifying operates continuously regardless of the humidity.
(b) The constant compressor, cool air and warm air fans operate continuously.
(c) Perform cool air operation by placing the damper position in cool air mode.
(d) Control fl uctuations by changing the cool air fan rank level by time.
Change the cool air/warm air fan rank as follows.
When the room temperature is 36˚C or more, the warm air fan rank is fi xed at rank 5.
Step Cool air fan Warm air fan Conditions for moving to next step
Step1 Rank1 Rank4 Operation after 5 seconds
Step2 Rank4 Rank4 Operation after 2 seconds
Step3 Rank8 Rank4 Operation after 5 seconds
The step switching order is as follows.
(a) Step 1 2 3 2 1 ...
COOL AIR/VARY operation is disabled in the following cases.
(a)
When the LAUNDRY switch is pressed, it switches to the previously set LAUNDRY operation mode (HIGH, NORMAL or HEAVY).
(b) When the DEHUMIDIFYING switch is pressed, it switches to the previously set DEHUMIDIFYING operation
mode (DEHUMIDIFYING LOW, DEHUMIDIFYING HIGH or AUTO).
(c) When the SPOT AIR switch is pressed, it switches to WARM AIR operation.
(d) When the DEO-DRY switch is pressed, it switches to the DEO-DRY mode operation.
DEO-DRY mode operation
Control Summary
(a) Odors are removed by heating the clothes.
(b) The following operations are performed during clothes deodorization.
Target part Compressor Cool air fan Warm air fan Solenoid valve Louvre Damper
Operation ON Rank control Rank control OFF
Operation
mode
Cool Air
Warm air
Startup conditions
(a) When operation is on while DEO-DRY mode operation is selected
(b) When DEO-DRY mode operation is selected by operating the DEO-DRY switch
(c) When the DEO-DRY switch is pressed during clothes deodorization, DEO-DRY mode operation is restarted
from the following step 1.
Operating Contents
(a) Clothes equipment operates in order of the following steps.
- Step 1 Cool air is blown through the clothes
- Step 2 Warm air is blown through the clothes
(b) Control panel operation during the above mentioned steps
Step
Cool air
fan
Warm air
fan
Compressor
Solenoid
valve
Damper Conditions for moving to next step
Step1
Rank4
(Room temperature
35˚C or less)
Rank4
(Room temperature
35˚C or less)
ON OFF Cool Air Operates for 20 min.
Step2
Rank4
(Room temperature
35˚C or less)
Rank4
(Room temperature
35˚C or less)
ON OFF Warm air
After 40 minutes operation, DEO-DRY
mode operation ends
DEO-DRY mode operation stopping condition
(a) Ends at the above mentioned step 2
(b) When the POWER switch is off
After DEO-DRY mode operation, it is disabled in the following cases.
(a)
When the LAUNDRY switch is pressed, it switches to the previously set LAUNDRY operation mode (HIGH, NORMAL or HEAVY).
(b) When the DEHUMIDIFYING switch is pressed, it switches to the previously set DEHUMIDIFYING operation
mode (DEHUMIDIFYING LOW, DEHUMIDIFYING HIGH or AUTO).
(c) When the SPOT AIR switch is pressed, it switches to the previously set SPOT AIR operation mode (COOL
AIR/LOW, COOL AIR/VARY or WARM AIR).
(d) When the DEO-DRY switch is pressed, it restarts DEO-DRY mode operation from the fi rst stage (step 1).