Service manual

7
Laundry Operation
1. HIGH
Control Summary
(a) Dehumidifying operates continuously regardless of the humidity.
(b) The constant compressor, cool air and warm air fans operate continuously.
Target part Compressor Cool air fan Warm air fan Solenoid valve Louvre Damper
Operation ON Rank control Rank control OFF
Operation
mode
Dehumidifying
position
Laundry operations are disabled in the following cases.
(a) When the LAUNDRY switch is pressed, it switches to LAUNDRY (NORMAL) operation.
(b) When the DEHUMIDIFYING switch is pressed, it switches to the previously set DEHUMIDIFYING operation
mode (DEHUMIDIFYING LOW, DEHUMIDIFYING HIGH or AUTO).
(c) When the SPOT AIR switch is pressed, it switches to the previously set SPOT AIR operation mode (COOL AIR
LOW, COOL AIR VARY or WARM AIR).
(d) When the DEO-DRY switch is pressed, it switches to the DEO-DRY mode operation.
2. NORMAL or HEAVY
z NORMAL
Operating time From operation start to 30 minutes After 30 minutes or more
Fan temperature table 0 1 2 3
Damper
position
0123
Damper
position
Cool
air fan
Average
humidity
70%~80% Rank7 Rank7 Rank7 Rank5 Dehumidifying Rank7 Rank7 Rank7 Rank5 Dehumidifying
60%~69% Rank6 Rank7 Rank7 Rank5 Dehumidifying Rank6 Rank7 Rank7 Rank5 Dehumidifying
30%~59% Rank6 Rank7 Rank7 Rank5 Dehumidifying Rank6 Rank4 Rank4 Rank5 Warm air
Warm
air fan
Average
humidity
70%~80% Rank6 Rank6 Rank6 Rank5 Dehumidifying Rank6 Rank6 Rank6 Rank5 Dehumidifying
60%~69% Rank6 Rank6 Rank6 Rank5 Dehumidifying Rank6 Rank6 Rank6 Rank5 Dehumidifying
30%~59% Rank6 Rank6 Rank6 Rank5 Dehumidifying Rank4 Rank4 Rank4 Rank5 Warm air
z HEAVY
Operating time From operation start to 30 minutes After 30 minutes or more
Fan temperature table 0 1 2 3
Damper
position
0123
Damper
position
Cool
air fan
Average
humidity
70%~80% Rank7 Rank7 Rank7 Rank5 Warm air Rank7 Rank7 Rank7 Rank5 Warm air
60%~69% Rank6 Rank7 Rank7 Rank5 Warm air Rank6 Rank7 Rank7 Rank5 Warm air
30%~59% Rank6 Rank7 Rank7 Rank5 Warm air Rank6 Rank4 Rank4 Rank5 Warm air
Warm
air fan
Average
humidity
70%~80% Rank6 Rank6 Rank6 Rank5 Warm air Rank6 Rank6 Rank6 Rank5 Warm air
60%~69% Rank6 Rank6 Rank6 Rank5 Warm air Rank6 Rank6 Rank6 Rank5 Warm air
30%~59% Rank6 Rank6 Rank6 Rank5 Warm air Rank4 Rank4 Rank4 Rank5 Warm air
Control Summary
(a) The dehumidifying time changes depending on the humidity, temperature and time.
(b) The time when the humidity changes is measured, and dehumidifying operation is automatically stopped when
the laundry is dry.
(c) Normal
Target part Compressor Cool air fan Warm air fan Solenoid valve Louvre Damper
Operation ON Rank control Rank control OFF
Operation
mode
Dehumidifying
Warm air
*The damper switches when humidity drops below 60%
(d) Heavy
Target part Compressor Cool air fan Warm air fan Solenoid valve Louvre Damper
Operation ON Rank control Rank control OFF
Operation
mode
Warm air