Instruction manual

4 Insert the hose into the drainage
outlet on the back.
1 Feed the commercially available hose (ID 15
mm) into the drainage outlet while keeping the
stopper pressed.
2 Feed the hose into the
drainage outlet.
3 Confirm that the hose
is securely attached
and does not leak.
5 Replace the tank, and set the end
of the hose in the drain.
The unit cannot operate without returning the tank.
22
Continuous Drainage
If a drain is available, the unit can continuously drain excess water by attaching a commercially available hose
(internal diameter 15mm).
The unit can be operated for extensive periods without the need to empty the water tank.
1 Remove the water tank.
2 Open the drainage outlet.
3 Press drain stopper.
CAUTION
Open the front door. Grasp handle and
pull out.
Drain
Stopper
Push here
¡hose immersed in
water
¡hose raised to a
level higher than
the drainage outlet
/The water will not
drain.
Note
Hose
Leave a minimum space of 20 cm behind the unit for attaching the hose.
Confirm that the hose does not show signs of deterioration such as cracks and clogging.
Inspect the hose every 2 weeks. Insects or dirt blocking the hose may cause leakage resulting in
malfunctions.
How to set up the drainage hose
Correctly installed
Incorrectly
installed
Necessary
items
¡Commercially available hose (ID 15mm)
Long enough to reach the drain.
¡Side Cutters
Do not drain water continuously if there
is a possibility that temperatures around
the hose could drop below freezing point.
Water inside the hose may freeze and water may leak
from the unit and
damage surrounding objects.
When draining water continuously or left
unattended for long periods, inspect the
unit once a fortnight.
Foreign objects, etc. could clog the hose
resulting in overheating and/or leakage.
Use cutters to cut the three
fixing ribs of the continuous
drainage port on the back of
the main unit, then remove it
carefully making sure that it
does not fall inside the unit.
Position of drainage outlet
e_mj_e22vx_a1(20_28)_e33.qx 11/26/04 10:01 AM Page 22