Owner manual

3 - 23
3. SIGNALS AND WIRING
2) Output pulse
Servo motor CCW rotation
LA
LAR
LB
LBR
LZ
LZR
T
/2
400 s or more
OP
The time cycle (T) is determined by
the setting of the parameter No. 27 and 58.
(4) Analog input
Input impedance 10k to 12k
Upper limit setting 2k
15VDC
P15R
VC‚ etc
LG
SD
2k
Servo amplifier
Approx.
10k
(5) Analog output
Output voltage
10V
Max.1mA
Max. output current
Resolution : 10bits
MO1
(MO2)
LG
SD
A
Servo amplifie
r
Reading in one or
both directions
1mA meter
10k