Service manual

49
SW2 setting
1
ON
23456
Display detail
Explanation for display
Unit
Capacity setting display
Displayed as an outdoor capacity code.
Code
display
1
ON
23456
1
ON
23456
Outdoor unit setting information
Indoor pipe temperature / Liquid (TH2(1))
Indoor 1
-39 – 88
Code
display
:
-39 – 88
(When the temperature is 0°C or less, “–” and
temperature are displayed by turns.)
1
ON
23456
1
ON
23456
Indoor room temperature (TH1)
8 – 39
Capacity Code
SW40V 9
SW50V 10
Setting details
• The tens digit (Total display for applied setting)
• The ones digit
H·P /
Cooling only
Single phase / 3 phase
Display details
0 : H·P 1 : Cooling only
0 :
Single phase
2 :
3 phase
Setting details
Defrosting switch
Display details
0 : Normal 1 : For high humidity
(Example) When heat pump, 3 phase and defrosting
(normal) are set up, “20” is displayed.
1
ON
23456
1
ON
23456
Indoor pipe temperature / Cond. / Eva.
(TH5(1))
Indoor 1
-39 – 88
-39 – 88
(When the temperature is 0°C or less, “–” and
temperature are displayed by turns.)
:
-39 – 88
(When the temperature is 0: or less, “–” and
temperature are displayed by turns.)
-39 – 88
(When the temperature is 0°C or less, “–” and
temperature are displayed by turns.)
:
:
:
8 – 39
Indoor pipe temperature / Liquid (TH2(2))
Indoor 2
-39 – 88
Indoor pipe temperature / Cond. / Eva.
(TH5(2))
Indoor 2
-39 – 88
1
ON
23456
The number of connected indoor units
Unit
0 – 4
(The number of connected indoor units are displayed.)
The black square ( ) indicates a switch position.
OCH525