Specifications

22
INDOOR COMBINATION
COOL
HEAT
OPERATION
RANGE
Capacity [kW]
Air Volume (High) [L/s]
Connection Method (Indoor / Outdoor side)
Power Supply. [V,Phase,Hz]
Cooling [
o
C]
Heating [
o
C]
2 to 8 Indoor Units
TYPE
MODEL NAME
Inverter Multi-Split
MXZ-8A140VA
Outdoor Unit SpecificationsOutdoor Unit Specifications
Rating Conditions Cooling — Indoor: 27°C DB, 19°C WB Outdoor: 35°C
( AS / NZS 3823 ) Heating — Indoor: 20°C DB Outdoor: 7°C DB, 6°C WB
*1 In case of connecting 3 units of MSZ-GA60VA. The Electrical data is only for outdoor unit.
*2 Including branch box and indoor units (3 units of MSZ-GA60VA).
*3 See Piping Length and Height Differential Table.
MXZ-8A140VA Inverter Power Multi-Split Outdoor Unit (R410A)
Piping Length and Height Differential TablePiping Length and Height Differential Table
Additional Refrigerant Charge
External Wiring (Power supply intake : Outdoor unit only)
Connectable Indoor Unit Specifications for MXZ-8A140VAConnectable Indoor Unit Specifications for MXZ-8A140VA
Connectable Indoor Units
MSZ-GA22VA
MSZ-FA25VA, MSZ-GA25VA, MFZ-KA25VA, SLZ-KA25VA(L)
MSZ-FA35VA, MSZ-GA35VA, MFZ-KA35VA, SEZ-KA35VA, SLZ-KA35VA(L)
MSZ-GA50VA, MFZ-KA50VA, SEZ-KA50VA, SLZ-KA50VA(L)
MSZ-GA60VA, SEZ-KA60VA
MSZ-GA71VA, PEA-RP71EA, PLA-RP71AA
Class (kW)
2.2
2.5
3.5
5.0
6.0
7.1
Equivalent models
MSZ-FA Series Wall Mounted MSZ-GA Series Wall Mounted
Model Name
Rated Capacity Cooling (Heating)
Pipe Size (Liquid / Gas)
Air Flow
Sound Level
Dimensions
Weight
MSZ-FA25VA
2.5 (3.6)
6.35 / 9.52
70 - 132 - 165
73 - 138 - 170
21 - 36 - 42
298
780
198
10
MSZ-FA35VA
3.5 (4.0)
6.35 / 9.52
72 - 132 - 165
77 - 138 - 170
22 - 36 - 42
298
780
198
10
*
SH = Super High
*
SH = Super High
Cooling
Heating
[Low-Hi-SH*]
H
W
D
kW
mm
L/s
dB (A)
mm
mm
mm
kg
[Low-Hi-SH*]
Model Name
Rated Capacity Cooling (Heating)
Pipe Size (Liquid / Gas)
Air Flow
Sound Level
Dimensions
Weight
MSZ-GA60VA
6.0 (7.9)
6.35 / 15.88
145 - 287
32 - 54
325
1,100
258
16
MSZ-GA50VA
5.0 (7.2)
6.35 / 12.7
138 - 237
31 - 48
325
1,100
258
16
MSZ-GA35VA
3.5 (4.0)
6.35 / 9.52
68 - 133 - 167
75 - 140 - 175
22 - 36 - 43
298
780
210
9
MSZ-GA25VA
2.5 (3.6)
6.35 / 9.52
65 - 133 - 167
72 - 140 - 175
21 - 36 - 43
298
780
210
9
MSZ-GA22VA
2.2 (3.3)
6.35 / 9.52
65 - 133 - 167
72 - 140 - 175
21 - 36 - 43
298
780
210
9
MSZ-GA71VA
7.1 (8.6)
6.35 / 15.88
157 - 287
33 - 54
325
1,100
258
16
Cooling
Heating
[Low-Hi-SH*]
H
W
D
kW
L/s
dB (A)
mm
mm
mm
kg
[Low-Hi-SH*]
MFZ-KA Series Floor Standing
Model Name
Rated Capacity Cooling (Heating)
Pipe Size (Liquid / Gas)
Air Flow
Sound Level
Dimensions
Weight
MFZ-KA25VA
2.5 (3.6)
6.35 / 9.52
80 - 118 - 145
83 - 127 - 152
22 - 32 - 37
600
700
200
14
MFZ-KA35VA
3.5 (4.0)
6.35 / 9.52
83 - 123 - 152
87 - 130 - 158
23 - 33 - 38
25 - 33 - 38
600
700
200
14
MFZ-KA50VA
5.0 (7.2)
6.35 / 12.7
118 - 153 - 178
123 - 163 - 197
32 - 39 - 43
32 - 39 - 44
600
700
200
14
*
SH = Super High
*
SLZ-KA
**
VAL : Includes Wireless Remote Controller.
*
SLZ-KA
**
VA : Includes PAR-21MAA - 7 Day Wall Controller.
*
SEZ-KA
**
VA : Includes PAR-21MAA - 7 Day Wall Controller.
Cooling
Heating
Cooling
Heating
H
W
D
kW
mm
L/s
dB (A)
mm
mm
mm
kg
[Low-Hi-SH*]
[Low-Hi-SH*]
SLZ-KA Series Ceiling Cassette
Model Name
Rated Capacity Cooling (Heating)
Pipe Size (Liquid / Gas)
Air Flow
Sound Level
Dimensions
Weight
Panel
SLZ-KA25VA(L)
*
2.5 (3.6)
6.35 / 9.52
133 - 167
28 - 37
208
570
570
20 x 650 x 650
16.5 (3)
SLZ-KA35VA(L)
*
3.5 (4.0)
6.35 / 9.52
133 - 183
29 - 38
208
570
570
20 x 650 x 650
16.5 (3)
SLZ-KA50VA(L)
*
5.0 (7.2)
6.35 / 12.7
133 - 183
30 - 39
208
570
570
20 x 650 x 650
16.5 (3)
[Low-Hi]
[Low-Hi]
H
W
D
H x W x D
Unit (Panel)
kW
mm
L/s
dB (A)
mm
mm
mm
mm
kg
SEZ-KA Series Ceiling Concealed
Model Name
Rated Capacity Cooling (Heating)
Pipe Size (Liquid / Gas)
Air Flow
Static Pressure
Sound Level
Dimensions
Weight
SEZ-KA35VA
*
3.5 (4.0)
6.35 / 9.52
167 - 217
Std:30, Max:50
30 - 35
270
1,100
700
33.5
SEZ-KA50VA
*
5.0 (7.2)
6.35 / 12.7
200 - 283
Std:30, Max:50
31 - 39
270
1,100
700
33.5
SEZ-KA60VA
*
6.0 (7.9)
6.35 / 15.88
200 - 333
Std:30, Max:50
32 - 43
270
1,100
700
33.5
[Low-Hi]
[Low-Hi]
H
W
D
kW
mm
L/s
Pa
dB (A)
mm
mm
mm
kg
*
PLA-RP
**
AA : Includes PAR-21MAA - 7 Day Wall Controller.
*
PLA-RP
**
AA : (Optional) Wireless Remote Controller.
PLA-RP Series Ceiling Cassette
Model Name
Rated Capacity Cooling (Heating)
Pipe Size (Liquid / Gas)
Air Flow
Sound Level
Dimensions
Weight
Panel
PLA-RP71AA
*
7.1 (8.6)
6.35 / 15.88
250 - 333
28 - 34
258
840
840
30 x 950 x 950
24 (5)
[Low-Hi]
[Low-Hi]
H
W
D
H x W x D
Unit (Panel)
kW
L/s
dB (A)
mm
mm
mm
mm
kg
*
PEA-RP**EA : Includes PAR-21MAA - 7 Day Wall Controller.
PEA-RP Series Ceiling Concealed
PAC-AK**BC Branch Boxes
Model Name
Rated Capacity Cooling (Heating)
Pipe Size (Liquid / Gas)
Air Flow
Static Pressure
Sound Level
Dimensions
Weight
PEA-RP71EA
*
7.1 (8.6)
6.35 / 15.88
367 - 450
125
52 - 55
428
785
690
46
[Low-Hi]
[Low-Hi]
H
W
D
kW
L/s
Pa
dB (A)
mm
mm
mm
kg
Additional refrigerant charge is not necessary for this unit if the total pipe length
( A + B + C + D + E + F + G + H + I + J ) does not exceed 40m.
If the total pipe length exceeds 40m, charge the unit with additional R410A refrigerant according
to the pipe lengths, referring to the chart below.
The single-phase power supply is needed only
for the outdoor unit. The branch box and indoor
units are powered by the outdoor unit through
transmission wiring. Work on the power supply,
therefore, should be carried out at only one
location.
Breaker: Interrupting current - 40A /
Performance characteristics - 40A, 30mA for
0.1 sec. or less.
IMPORTANT
Make sure that the current leakage breaker is
the one compatible with higher harmonics.
Always use a current leakage breaker that is
compatible with higher harmonics as this unit
is equipped with an inverter.
The use of an inadequate breaker can cause
the incorrect operation of inverter.
Total piping length
( A + B + C + D + E + F + G + H + I + J )
40m or less
0kg (no need)
40 - 50m
0.9kg
51 - 70m
1.7kg
71 - 90m
2.5kg
91 - 115m
3.5kg
Additional refrigerant charging amount
Input *1 [kW]
COP (In + out) *2
(Silent)
[dB
(A)
]
Current Running
(Rated)
[A]
Sound Level
(Rated)
[dB
(A)
]
Air Volume (High) [L/s]
Capacity [kW]
Input *1 [kW]
COP (In + out) *2
Sound Level
(Rated)
[dB
(A)
]
Current Running
(Rated)
[A]
Current Starting [A]
Current Running
(Max.)
[A]
OUTDOOR
EXT. PIPE
Total Capacity of all indoor units [kW]
Gas (diameter) [mm]
Max. Length
(Total)
*3 [m]
Max. Height *3 [m]
Precharged [m]
Dimension (HxWxD) [mm]
Weight [kg]
Liquid (diameter) [mm]
14.0
3.79
3.52
50
47
16.55
1667
16.0
3.90
3.91
52
17.05
1667
29.5
14
4.4 to 18.5
1350 x 950 x 330
128
9.52
15.88
115
30
40
Flared / Flared
220 / 230 / 240, single, 50
-5 / +46
-10 / +21
Type
Ty pe
Model Name
Connectable Number of Indoor Units
Power Supply [Source, V, Phase, Hz]
Power Input
Running Current
Drain Hose* Size
Dimensions [HxWxD]
Weight
kW
A
mm
mm
kg
Piping [diameter]
Branch [Indoor side] Liquid
Gas
LiquidMain [Outdoor side]
Gas
mm
Wiring
Branch Box
Branch Box
PAC-AK50BC
Max. 5
from Outdoor Unit, 220 / 230 / 240, single, 50
0.003
0.05
O.D. 20 (VP-16)
198x450x280
9.3
6.35x5
3-wire + Earth wire
to Indoor Unit
Connection Method
to Outdoor Unit
Flared
3-wire + Earth wire
mm
mm
mm
9.52x4, 12.7x1
9.52
15.88
PAC-AK30BC
Max. 3
0.003
0.05
8.1
6.35x3
Flared
9.52x3
9.52
15.88
*To be locally purchased
C
D
B
A
E
F
G
H
I
J
Branch
box
Branch
box
Joint pipe (optional)
(A+B+C+D+E+F+G+H+I+J)
(A+B)
(C+D+E+F+G+H+I+J)
(Each C, D, E, F, G, H, I, J)
(Farthest)
Outdoor - Indoor
Outdoor - Branch Box
Branch Box - Indoor
Indoor - Indoor
In case of installing the outdoor unit lower than indoor unit : 20m.
ALL