Submittal
Specications are subject to change without notice. © 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.
Job Name:
System Reference: Date:
MODEL: XXXXXXXMODEL: MHK2 kumo touch™
MRCH2 REMOTE CONTROLLER SPECIFICATIONS
• Touch panel, Backlit, easy-to-read display
• Used RedLINK™ 3.0 wireless technology
- Not compatible with MHK1, MOS1, and MCCH1 RedLINK 2.0
wireless technology environment.
• User functions allow user to set:
- On/Off
- Operation modes cool, heat, drying, fan
- Set temperature (separate dual set points for heat and cool)
- Fan speed setting
- Airow direction
• Set temperature range limits (dependent on the system connected):
- Cooling from 50° to 99° F
- Heating from 40° to 90° F
- Auto from 50° to 90° F with dual temperature setting
• MHK2 Scheduling options:
- No Schedule
- MO-SU = Every day the same
- MO-FR, SA, SU = 5-1-1 schedule
- MO-FR, SA-SU = 5-2 schedule
- Each Day = Every day individual
- Allow kumo cloud to be schedule holder
• Hold function
• Temporary or Permanent schedule override
• Lockout:
- On
- Off
- Mode
- Fan Speed
- Set point
- Vane Direction
• Day/Time display with a 12 or 24-hour clock
• Supports both Fahrenheit and Celsius
• RedLINK™ Wireless Connection Status
• Filter sign display
• Diagnostics: Displays and records error codes
• Adjustable auto mode deadband
• Space temperature offset adjustment
• Space humidity offset adjustment
• Hide (on screen only)
- Indoor temperature
- Indoor humidity
• Temperature Sensing Source
- MHK2
- Indoor Unit
- RedLINK Wireless Indoor Air Sensor (IAS)
- Average of MHK2 and RedLINK Wireless Indoor Air Sensor (IAS)
• Indoor Humidity Source
- MHK2
- RedLINK Wireless Indoor Air Sensor (IAS)
- Average of MHK2 and RedLINK Wireless Indoor Air Sensor (IAS)
• Improved indoor unit function code list
- Indoor unit type
- Expanded to 28 indoor unit codes
• Reset to factory default
• Uses two “AA” alkaline batteries (included)
• Dimensions: 4-5/64” x 4-5/64” x 1-1/16” (104 x 104 x 27 mm)
• Operating Ambient Temperature: 32° to 120° F (0° to 48.9° C)
• Operating Relative Humidity: 5% to 90%
MIFH2 WIRELESS RECEIVER SPECIFICATIONS:
• Included in MHK2 Kit
• Mounts next to or near indoor units to allow MRCH2 Remote
Controller operation
• Connects to indoor unit control board with MRC2 Cable
• Dimensions: 3-3/32” H x 1-3/4” W x 39/64” D (74.8 x 44.4 x 15.4
mm)
• Operating Ambient Temperature: -40° to 165° F (-40° to 73.9° C)
• Operating Relative Humidity: 5% to 95%
MRC2 CABLE
• Included in MHK2 Kit in the MIFH2 box
• Connects MIFH2 Wireless Receiver to the CN105 connector on
indoor unit control board
• Length: 39-23/64" (1 m)
MRCH2
MIFH2
MRC2