Engineering Manual

A-129
Refrigerant piping length (one way: ft.)
25 (std.) 40 65 100
MUZ-FH06/09/12NA
MUZ-FH06/09/12NAH
1.0 0.988 0.967 -
MUFZ-KJ09/12NAHZ
MUZ-FE09/12NAH
MUZ-FH15NA
MUZ-FH15NAH
MUZ-FH18NA2
MUZ-FH18NAH2
1.0 0.985 0.963 0.933
MUFZ-KJ15/18NAHZ
Max. Length
A
Max. Height
difference
B
Indoor
unit
Outdoor unit
7-3.3 Max. refrigerant piping length and max. height difference
Model
Refrigerant piping: ft. Piping size O.D: in.
Max. Length
A
Max. Height difference
B
Gas Liquid
MUZ-FH06/09/12NA
MUZ-FH06/09/12NAH
65 40 3/8 1/4
MUFZ-KJ09NAHZ
MUFZ-KJ12NAHZ
MUZ-FH15NA
MUZ-FH15NAH
MUZ-FH18NA2
MUZ-FH18NAH2
100 50 1/2 1/4
MUFZ-KJ15NAHZ
MUFZ-KJ18NAHZ
7-3. HYPER HEATING INVERTER
7-3.1 Cooling capacity corrections
7-3.2 Heating capacity corrections
Refrigerant piping length (one way: ft.)
25 (std.) 40 65 100
MUZ-FH06/09/12NA
MUZ-FH06/09/12NAH
1.0 0.977 0.993 -
MUFZ-KJ09/12NAHZ
MUZ-FE09/12NAH
MUZ-FH15NA
MUZ-FH15NAH
MUZ-FH18NA2
MUZ-FH18NAH2
1.0 0.977 0.993 0.987
MUFZ-KJ15/18NAHZ