8-4. STANDARD OPERATION DATA
MS-A09WA
Cooling
9500
0.68
0.87
MS-A09WA
115, 1, 60
0.019
0.27
MU-A09WA
115, 1, 60
0.851
6.74
0.63
372
144
154
110
48
146
25
2lb. 5oz.
80
67
57
56
1160
300 (Wet)
95
830
1083
Capacity
SHF
Input
INDOOR UNIT MODEL
Power supply (V, phase, Hz)
Input
Fan motor current
OUTDOOR UNIT MODEL
Power supply (V, phase, Hz)
Input
Comp. current
Fan motor current
Condensing pressure
Suction pressure
Discharge temperature
Condensing temperature
Suction temperature
Comp. shell bottom temp
Ref. pipe length
Refrigerant charge (R410A)
Intake air temperature
Discharge air temperature
Fan speed (High)
Airflow (High)
Intake air temperature
Fan speed
Airflow
Unit
Btu / h
kW
kW
A
kW
A
A
PSIG
PSIG
°F
°F
°F
°F
ft.
°F
°F
°F
°F
rpm
CFM
°F
°F
rpm
CFM
MS-A12WA
Cooling
12000
0.70
1.07
MS-A12WA
115, 1, 60
0.035
0.51
MU-A12WA
115, 1, 60
1.035
7.96
0.93
375
150
149
111
50
139
25
3lb. 1oz.
80
67
59
58
1220
363 (Wet)
95
830
1327
DB
WB
DB
WB
DB
WB
Item
Model
Total
Electrical
circuit
Refrigerant
circuit
Indoor
unit
Outdoor
unit