Engineering Manual

B-127
7
NECESSARY CONDITIONS FOR SYSTEM CONSTRUCTION
REFRIGERANT SYSTEM DIAGRAM
MXZ-8C48NA
MXZ-8C60NA
Distributor
Service port
Ball valve
Strainer
4-Way Valve
(21S4)
Accumulator
High pressure
switch(63H)
Compressor
LEV-A
LEV-B
HIC
Oil separator
Solenoid valve(SV1)
<Bypass>
Stop valve
Service port
Low pressure
sensor(63LS)
Capillary
tube1
Thermistor(TH4)
<Compressor>
Thermistor(TH6)
<Suction pipe>
Thermistor(TH2)
<HIC pipe>
Refrigerant flow in cooling
Room temperature
thermistor
(TH1 or RT11)
Condenser /
evaporator
temperature
thermistor
Pipe temperature
thermistor
(TH2 or RT13)
LEV-A~E
(Linear expansion)
Thermistor(TH-A–E)
<Gas pipe temperature>
Service port
Strainer
Strainer
StrainerStrainer
Strainer
Strainer
Service port
High
pressure
sensor(63HS)
Thermistor(TH7)
<Ambient>
Thermistor(TH3)
<Outdoor Liquid pipe>
Thermistor(TH8)
<Heat Sink>
Refrigerant flow in cooling
Refrigerant flow in heating
Branch box
Strainer
Capillary
tube2
Indoor
Outdoor unit
Outdoor unit
MXZ-8C48NA
PAC-MKA51BC
PAC-MKA31BC
Branch box
Capillary tube 1
(For return of oil from oil separator)
Capillary tube 2 behind LEV
(in cooling mode)
ø0.098 x ø0.031 x L(39-1/2)
(ø2.5 x ø0.8 x L1000)
(ø0.157 x ø0.117 x L(5-1/8)) x 5
((ø4 x ø3.0 x L130) x 5)
(ø0.157 x ø0.117 x L(5-1/8)) x 3
((ø4 x ø3.0 x L130) x 3)
Unit: inch (mm)
Distributor
Service port
Ball valve
Strainer
4-Way Valve
(21S4)
Accumulator
High pressure
switch(63H)
Compressor
LEV-A
LEV-B
HIC
Oil separator
Solenoid valve(SV1)
<Bypass>
Stop valve
Service port
Low pressure
sensor(63LS)
Capillary
tube1
Capillary
tube2
Thermistor(TH4)
<Compressor>
Thermistor(TH6)
<Suction pipe>
Thermistor(TH2)
<HIC pipe>
Refrigerant flow in cooling
Room temperature
thermistor
(TH1 or RT11)
Condenser /
evaporator
temperature
thermistor
Pipe temperature
thermistor
(TH2 or RT13)
LEV-A~E
(Linear expansion)
Thermistor(TH-A–E)
<Gas pipe temperature>
Service port
Strainer
Strainer
StrainerStrainer
Strainer
Strainer
Service port
High
pressure
sensor(63HS)
Thermistor(TH7)
<Ambient>
Thermistor(TH3)
<Outdoor Liquid pipe>
Thermistor(TH8)
<Heat Sink>
Refrigerant flow in cooling
Refrigerant flow in heating
Branch box
Strainer
Capillary
tube3
Indoor
Outdoor unit
Outdoor unit
MXZ-8C60NA
PAC-MKA51BC
PAC-MKA31BC
Branch box
Capillary tube 1
(For return of oil from oil separator)
Capillary tube 3 behind LEV
(in cooling mode)
ø0.098 x ø0.031 x L(39-1/2)
(ø2.5 x ø0.8 x L800)
(ø0.157 x ø0.117 x L(5-1/8)) x 5
((ø4 x ø3.0 x L130) x 5)
(ø0.157 x ø0.117 x L(5-1/8)) x 3
((ø4 x ø3.0 x L130) x 3)
Capillary tube 2
(For solenoid valve (SV1))
ø4.0 x ø3.0 x L500
Unit: inch (mm)