Engineering Manual

B-153
OUTLET AIR SPEED AND COVERAGE
● The air coverage is the figure up to the
position where the air speed is 1 ft./s,
when air is blown out horizontally from
the unit properly at the High speed
position.
The coverage should be used only
as a general guideline since it varies
according to the size of the room and
furniture arranged inside the room.
Model Mode Function
Airow
(CFM)
Air speed
(ft./s)
Coverage
(ft.)
MSZ-EF09NAW
MSZ-EF09NAB
MSZ-EF09NAS
HEAT Dry 420 19.5 29.2
COOL
Dry 371 17.2 25.8
Wet 319 14.8 22.3
MSZ-EF12NAW
MSZ-EF12NAB
MSZ-EF12NAS
HEAT Dry 448 20.8 31.1
COOL
Dry 371 17.2 25.8
Wet 319 14.8 22.3
MSZ-EF15NAW
MSZ-EF15NAB
MSZ-EF15NAS
HEAT Dry 448 20.8 31.1
COOL
Dry 364 16.8 25.4
Wet 313 14.5 21.9
MSZ-EF18NAW
MSZ-EF18NAB
MSZ-EF18NAS
HEAT Dry 466 21.6 32.3
COOL
Dry 388 18.0 27.0
Wet 334 15.5 23.4