Engineering Manual

B-188
*1
*1
*3
*3
*2
141 (64)
0.340
NOTE:
36,000
10.6
11.7
m
3
/min 21.7 - 26.4 - 31.0
External dimension HxWxD inch 54-1/4 x 21 x 21-5/8
Net weight
Motor Type
Gas
(R410A)
*1.Nominal cooling conditions
Indoor: 80 º FD.B./67 º FW.B. (26.7 º CD.B./19.4 º CW.B.), Outdoor: 95 º FD.B. (35 º CD.B.)
Pipe length: 25 ft. (7.6 m), Level difference: 0 ft. (0 m)
*2.The values are measured at the factory setting of external static pressure.
*3.Nominal heating conditions
Indoor: 70 º FD.B. (21.1 º CD.B.), Outdoor: 47 º FD.B./43 º FW.B. (8.3 º CD.B./6.1 º CW
.B.)
Pipe length: 25 ft. (7.6 m), Level difference: 0 ft. (0 m)
*4.The factory setting of external static pressure is shown without < >.
Refer to "AIR FLOW DATA", according to the external static pressure, in DATA BOOK for the usable
range of air flow rate.
*2 Power input
Power source 1-phase 208/230 V 60 Hz
0.340 kW
BTU/h
kW
Cooling capacity
3/8 (9.52)Flare
inch (mm)
inch (mm)
3/4 (19.05) FPT
5/8 (15.88)Flare
Field drain pipe size inch (mm)
(Low-Mid-High)
767 - 931 - 1,095
L/s
dB <A>
Sound pressure level
Fuse
(R410A)
Liquid
Dia
meter of
refrigerant pipe
Protection device
BTU/h
*2
lbs (kg)
Air flow rate
3.00/2.70
Cross fin (Aluminum fin and copper tube)
Current input A
in.WG
External
static press.
*4
Current input
Heating capacity
A
kW
*2
Motor output kW
*2 Power input kW
cfm
Pa
FAN
Heat exchanger
Type x Quantity
40,000
1,378 x 534 x 548
<0.30> - 0.50 - <0.80>
3.00/2.70
mm
Sirocco fan x 1
(Low-Mid-High)
0.244
35-39-43
362 - 440 - 517
DC motor
<75> - 125 - <200>
MVZ-A36AA7