125
A.6.120 UNITFAULTTRAPS
Name
UnitFaultTraps
OID
1.3.6.1.4.1.6247.21.1.10.0.1
Full path
iso(1).org(3).dod(6).internet(1).private(4).enterprises(1).comtech(624
7).cdm600l(21).cdm600lObjects(1).trapNotifications(10).trapNotificati
onsPrefix(0).unitFaultTraps(1)
Module
CDM600L
Parent
trapNotificationsPrefix
Type
NOTIFICATION-TYPE
Status
current
Objects
1
unitFaults
Description
Unit Fault Trap Using unitFaults. Whare abcd.
a = Unit faults
0 = No faults
1 = Power supply fault, +5 volts
2 = Power supply fault, +12 volts
3 = Power supply fault, -5 volts
4 = Power supply fault, +18 volts
5 = Power supply fault, -12 volts
6 = RAM load fail
7 = Tx synthesizer lock
8 = Rx synthesizer
9 = Power cal Checksum error
A = FPGA main chain load fail
B = Turbo FPGA load fail
C = Modem card FPGA load
D = MUX FPGA load
E = Demux FPGA load
b = Tx Traffic status
0 = Tx traffic OK
1 = No clock from terrestrial interface
2 = Tx FIFO slip
3 = AIS detected on incoming data
4 = AUPC upper limit reached
5 = Ref PLL
6 = BUC current
7 = BUC voltage
8 = BUC checksum
9 = BUC PLL
A = BUC temperature