user manual

CiM-25/600L IP Enabled M&C Rev. 1
Operation CD/CIM25600L.IOM
35
3.6 MAINTENANCE INTERFACE
The default network configuration settings are:
IP: 10.6.30.1
Admin Name: admin
Admin Password: 1234
The CiM-25 has been designed to support a means of allowing a customer to reset the
unit back to the factory default settings, change the IP Address, and verify the software
version. Use the following procedure to prepare for for making these changes.
Perform the following steps:
1
Disconnect the CiM-25 from both the interfacing equipment and the Ethernet Network.
2
Connect the CiM-25 to the serial port of a PC using a cable defined below (null cable):
CiM-25 pin 2 to PC pin 3
CiM-25 pin 3 to PC pin 2
CiM-25 pin 5 to PC pin 5
2
3
5
DB-9
2
3
5
DB-9
To CiM-25 Device
(M/F Depending on Unit)
To Computer
(Ususally Female)
Figure 1. Null Cable Diagram
3
Power the CiM-25 using the Power Jack connector and a external 5 Vdc power supply.
4
Using a Serial Communication application such as Terminal, ProComm, etc., configure the
PC’s serial port to:
Baud: 19200
Data rate: 8-N-1
Use the procedures in following sections to:
Reset to factory network defaults.
Change network IP Address
Verify software version.
Change MAC Address
Change Serial Number