Installation Guide

FH-W1802Vox Instructions14
3. Making the Electrical Connections
WARNING: Installation of this fan requires that a three-conductor
cable (including ground wire) which should run between ceiling and
wall outlet box.
WARNING: Check to see that all connections are tight, including
ground, and that no bare wire is visible at the wire nuts,
except for the ground wire.
Insert the receiver into the motor assembly with the at side of the
receiver facing the ceiling (Fig. 3).
Motor to Receiver & Receiver to house supply wires (Fig. 3A).
1. Connect the motor assembly ground wire, mounting bracket
ground wire and receiver ground wire to the ground wire in
outlet box.
WARNING: Failure to connect ground wires could result in
poor fan control functionality.
2. Connect the red wire from the fan to the red wire marked
TO MOTOR from the receiver.
3. Connect the grey wire from the fan to the grey wire marked
TO MOTOR from the receiver.
4. Connect the yellow wire from the fan to the yellow wire marked
TO MOTOR from the receiver.
5. Connect the white wire from the fan to the white wire marked
FOR LIGHT from the receiver.
6. Connect the blue wire from the fan to the blue wire marked
FOR LIGHT from the receiver.
7. Connect the black (hot) wire from the ceiling to the black wire
marked “AC in L from the receiver.
8. Connect the white (neutral) wire from the ceiling to the white
wire marked “AC in N from the receiver.