Installation & Assembly

Fig.1
PREPARATION
1. Shut off the power at the circuit breaker and remove existing fixture, including the crossbar.
2. Carefully unpack your new fixture and lay out all the parts on a clear area. Be careful not to lose any small parts
necessary for installation.
MOUNTING THE FIXTURE (Fig. 1)
3. Remove the mounting screw (B) from the fixture.
4. Drill holes in the wall aligned with the key holes located in the back plate, insert the plastic anchor (E)
5. Secure back plate to the junction box using standard junction box screws that comes with the junction box. Fasten it
to the wall using wood screw (D) onto the plastic anchor.
Note: (i) Using any other non-original-manufacturer provided junction box screw may result in safety issue;
(ii) The side of the mounting plate marked “GND” must face out.
6. Adjust the fixture wire length by pushing the cable gripper on the canopy and pulling the wire as desired.
a. Retract these wires close to a desirable length to within the canopy before securing the fixture in place.
Note: retracting or extending excessive cable length through the cable gripper is not recommended.
b. Warning: Shortening these cables without professional helps or electronic background is not advisable. Any modifications
to the fixture may result in voiding the warranty of the product.
CONNECTING THE WIRES (Fig. 2)
7. Connect the driver input/output wires with junction box wires as shown in Fig.2, making sure that all wire connectors
(A) are secured. If your outlet box has a green or bare copper ground wire, connect the fixture’s ground wire to it.
Otherwise, connect the fixture’s ground wire directly to the mounting plate using the green screw provided. After wires
are connected, tuck them carefully inside the junction box.
8. This fixture features electronic low voltage (ELV or TRAIC) or 0-10V dimming capabilities. See notes below for
specific dimming wiring information.
9. Secure the fixture to the back plate using the mounting screw (B).
10.
Remove the screw (C) and the glass cover from the fixture.
11.
Insert the glass into the fixture, secure the glass cover to the fixture with the screw (C).
NOTE: DIMMING WIRING INFORMATION (Fig. 3)
1. To utilize ELV or TRAIC dimming: use black (hot), white (neutral) and bare copper ground wires (ground).
2. To utilize 0-10V dimming: use purple (dim+), gray (dim-), black (hot), white (neutral) and bare copper ground wires (ground).
Modern Forms
www.modernforms.com
Phone (800) 526.2588 • Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive • Port Washington, NY 11050
Phone (516) 515.5000 • Fax (516) 515.5050
Western Distribution Center
1750 Archibald Ave • Ontario, CA 91761
Phone (800) 526.2588 • Fax (800)
526.2585
Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program.