PREPARATION
1. Shut o the power at the circuit breaker and remove
existing xture, including the crossbar.
2. Carefully unpack your new xture and lay out all the
parts on a clear area. Be careful not to lose any small
parts necessary for installation.
CONNECTING THE WIRES (Fig. 1)
3. Remove the mounting screw (E) from the mounting
back plate, take down the lamp body.
4. Drill holes in the wall aligned with the key holes located
in the mounting back plate, insert the plastic anchors
(D).
5. Remove the screw (F) from the End Cap, insert the
acrylic diuser into the xture, and fasten the End Cap
using at screws (F). Using Allen wrench (H) to adjust the
Allen screws (G) to keep the diuser locked in place.
6. Connect the Driver’s input wires to junction box wires
as shown in Fig. 2, making sure that all wire connectors
(A) are secured. If your outlet box has a green or bare
copper ground wire, connect the xture’s ground wire to
it. Otherwise, connect the xture’s ground wire directly
to the back plate using the green screw provided. After
wires are connected, tuck them carefully inside the
junction box.
*Requires Driver to be recessed within the junction
box
MOUNTING THE FIXTURE (Fig. 2)
7. Secure the mounting back plate to the junction box
using junction box screws (B); fasten it to the wall using
wood screw (C). The side of the mounting back plate
marked “GND” must face out.
8. Connect the driver’s output wires to the xture as
shown in Fig.2, making sure that all wire connectors are
secured.
9. Secure the lamp body onto mounting back plate with
mounting screw (E).
INSTALLATION INSTRUCTION
568 – LED Wall Sconce
WS-56827
G0
Fig.1
Mounting Backplate
(7MBC601304)
Fixture Wires
Black or
Smooth
Fixture Wires
White or
Ribbed
Fixture Wires
Bare wire
(Ground)
House Wires
Black
(Hot)
House Wires
White
(Neutral)
House Wires
Green or Bare Copper
(Ground)
Fig. 2 Wiring
=
E
C
_
D
F
G
=
H
Allen Wrench
Allen Screw
Acrylic Diuser
End Cap
Screw
Screw
Junction Box
Wire Connector
Driver 3” L x 1 1/4” W x 1 1/8” H
Junction Box Screw
Plastic Anchor
Mounting Plate
Wood Screw
Mounting Screw
Lamb Boby
Acrylic Diuser
23 5/8”
19 5/8”
1 3/4”
5 1/4”
1 3/8”
F
H
G
A
B
D
C
E