UNVENTED GAS RADIANT HEATER
FOR INDOOR (Non-Residential) INSTALLATION ONLY.
High - Intensity Infrared Heater
Class IIIA Permanent Label
262-636-1200 www.modine.com
VOLTS AC:
AMPS - STARTING:
AMPS - RUNNING:
120V - 60Hz
0.1
0.1
DESIGN COMPLIES WITH:
ANSI Z83.19 (latest edition) - Gas Fired High Intensity Infra-Red Heater
HEATER TYPE:
MANIFOLD PRESSURE:
MAX. INLET PRESSURE
C1
10.0 INCHES W.C.
14.0 INCHES W.C.
Serial No. 0807MODI123456001
MODEL NO.
IHR 60S 47
MIN. INLET PRESSURE FOR
PURPOSE OF ADJUSTMENT
MIN. MOUNTING ANGLE
MAX. MOUNTING ANGLE
INPUT BTU/H
60,000
FOR USE WITH
Natural Gas
VERSION
05/97
11.0 INCHES W.C.
20 DEGREES
35 DEGREES
IHR Series Manual
8
Safety Signs and Labels
It is important to provide warnings to alert individuals to potential hazards and safety actions. ANSI Z83.19
and the National Fuel Gas Code require you to post a sign “specifying the maximum permissible stacking
height to maintain the required clearances from the heater to the combustibles” near the heater’s thermostat
or in absence of such thermostats in a conspicuous location. Signs should state the hazards for the
particular application and be legible to the building occupants. Consult the factory or a factory representative
for additional information on signage compliance.
Safety warning labels must be maintained on the
infrared heater. Illustrations of the safety labels,
and their locations, are pictured below.
1.0 Safety Safety Signs and Labels
Back View
Bottom View
F/N: LLDCL002
Clearance to Combustibles Label
SAMPLE
MODINE MANUFACTURING COMPANY
1500 DEKOVEN AVENUE - RACINE, WI 53403
UNVENTED GAS RADIANT HEATER
FOR INDOOR (Non-Residential) INSTALLATION ONLY.
High - Intensity Infrared Heater
Class IIIA Permanent Label
www.modinehvac.com
VOLTS AC:
AMPS - STARTING:
AMPS - RUNNING:
120V - 60Hz
0.1
0.1
DESIGN COMPLIES WITH:
ANSI Z83.19 (latest edition) - Gas Fired High Intensity Infra-Red Heater
HEATER TYPE:
MANIFOLD PRESSURE:
MAX. INLET PRESSURE
C1
10.0 INCHES W.C.
14.0 INCHES W.C.
Serial No. 0807MODI123456001
MODEL NO.
IHR 60S 47
MIN. INLET PRESSURE FOR
PURPOSE OF ADJUSTMENT
MIN. MOUNTING ANGLE
MAX. MOUNTING ANGLE
INPUT BTU/H
60,000
FOR USE WITH
Natural Gas
VERSION
05/97
11.0 INCHES W.C.
20 DEGREES
35 DEGREES
1.800.828.4328 (HEAT)
Rating Plate
F/N: LLDR002
F/N: LL01 - Clearance
Safety Tag
(Affix adjacent to
heater’s thermostat)
CAUTION
Avoid Equipment Failure
Consult manual for installation guidelines.
Connect proper VO LTAG E as noted on gas valve and heater’s
rating label (25VAC or 120VAC).
Proper POLARITY must be observed. Hot line of electrical
source must be connected to black wire; neutral line to white wire.
For proper operation, green line must connect to POSITIVE
EARTH on all 120VAC heaters.
Observe listed inlet GAS PRESSURES.
Natural Gas: 7 Inches W.C. Min. 14 Inches W.C. Max.
L.P. Gas: 11 Inches W.C. Min. 14 Inches W.C. Max.
Observe 20°-35° MOUNTING ANGLE. DO NOT mount
horizontally. Consult installation manual.
Reference the WIRING DIAGRAM located inside this box.