INSTALLATION
This heater is intended for use as supplemental heat. Use this heater along with your
primary heating system. Do not install this heater as your primary heat source. If you
have a central heating system, you may run system’s circulating blower while using
heater. This will help circulate the heat throughout the house. In the event of a power
outage, you can use this heater as your primary heat source.
NOTICE
A qualified service person must install
heater. Follow all local codes.
WARNING
CHECK GAS TYPE: The gas supply
must be the same as stated on the
heaters rating plate. If the gas supply
is different, DO NOT INSTALL THE
HEATER. Contact your dealer for the
correct model.
CAUTION
INSTALLATION ITEMS
Before installing heater, make sure you have the items listed below.
• external regulator (supplied by installer for propane/LPG and 1/2 lb. natural gas systems)
• piping (check local codes) • pipe wrench • tee joint
• sealant (resistant to propane/LP gas) • equipment shutoff valve* • ground joint union
* A CSA design-certied equipment shutoff valve with 1/8” NPT tap is an acceptable alternative to test gauge connec-
tion. Purchase the optional CSA design-certied equipment shutoff valve from your dealer.