Installation Instructions

17
31-1000600 Rev. 1
DUAL INTEGRATED INSTALLATION
SPACE
Water And Electrical Locations
Electrical and water supply must be located as shown.
The Cutout Depth Must Be 25”
Cutout is based on installation of 2 products with a left-
and-right hand door swing.
Heater Unification Kit ZKUN required.
Product Clearances
These units are equipped with a 2-position door stop.
The factory set 115° door swing can be adjusted to 90° if
clearance to adjacent cabinets or walls is restricted.
For a 90° door swing, allow 4” (10.2 cm) minimum
clearance to a wall.
When installed in a corner, allow 15” (38.1 cm) for a full
115° door swing on 18” and 24” models. Allow 16.5”
(41.9 cm) on 30” models.
Additional Specifications
• A separate 115 volt 60Hz., 15 or 20 amp power supply
is recommended for each product. An individual
properly grounded branch circuit or circuit breaker is
recommended. Install a properly grounded 3-prong
electrical receptacle recessed into the back wall.
Electrical must be located on rear wall as shown.
• Water line must be located on the back wall as shown.
The water line should be 1/4” O.D. copper tubing or
QuickConnect
kit (WX08X10006) between the cold
water line and water connection location, long enough
to extend to the front of the unit (8’ [2.4m]). Installation
of an easily accessible shut-off valve in the water line is
required.
• A minimum of 6” finished return matching cabinet
exterior is recommended on interior on all sides and top
at front of opening.
• Installations with 6” (15.2 cm) or less between units
require Heater Unification Kit.
Design Guide - Dual Integrated Installation
TOOLS AND MATERIALS REQUIRED
Metal shears
#1, #2 Phillips screwdriver
Flathead screwdriver
Putty knife
Measuring tape
Drill and 1/16”, 5/64”, 3/16”, 1/2” bits
5/32” concrete bit (if installing anti-tip into concrete)
1/4”, 3/8”, 7/16” driver/socket
7/16” open wrench
T10, T20, T30 driver/bit
1/8”, 1/4” hex driver (allen wrench)
Level
Water shut-off valves (optional but recommended)
8’ waterline (one per unit requiring water hookup)
Masking tape
Rubbing alcohol
Adjustable wrench
Center punch
• Heater Unification Kit (ZKUN)
Stainless Steel Door Kits (if applicable)
Custom panels for doors (if applicable)
• ZKPN (If applicable)
Handle Kits (if applicable)
Small Ratchet
REFRIGERATOR/FREEZER LOCATION
Ŷ Do not install the refrigerator/freezer where the tem-
perature will go below 55°F (13°C). It will not run
often enough to maintain proper temperatures.
Ŷ Do not install the refrigerator/freezer where
temperatures will go above 100°F (37°C). It will not
perform properly.
Ŷ Do not install the refrigerator/freezer in a location
exposed to water (rain, etc.) or direct sunlight.
Ŷ Install it on a floor strong enough to support it fully
loaded.
HARDWARE SUPPLIED (per unit)
Water Filter Bypass Plug (if equipped)
Air filter (if equipped)
Anti-Tip bracket (qty 2 for 36”)
Lag screws
Tapcon screws
Panel installation templates
2 Door trims
2 Door panel brackets
Set screws
#6 Phillips head wood screws
Door Bracket Cover Top
T30 screws
1 Hinge limiter pin
Center door panel bracket
Hi-Lo screw and square washer
Stainless Toe Kick
Painted access cover screws
T10 screw