Owner's Manual

Installation Instructions - Flush Inset Installation
35
STEP 5 INSTALL SIDE PANELS
Skip this step when not using side panels.
If you are using 1/4” (0.63 cm) side panels, they should
be inserted into the case trim. Fasten the panels to the
refrigerator with stick-on hook and loop fastener strips
before setting the refrigerator in place.
STEP 4 INSTALLATION WITH
HOUSEHOLD WATER
FILTRATION SYSTEM
Skip this step if you do not have a household water
filtration system
If the water supply to the refrigerator is from any
household water filtration system, the filter cartridge
should be removed. For better ice and water
performance, remove the filter and install the filter
bypass plug.
Filter Bypass
Plug
Rotate Counterclockwise
to Remove
STEP 3 INSTALL WATER LINE (Cont.)
The tubing should be long enough to extend to the
front of the refrigerator. Allow enough tubing to
accommodate the bend leading into the water line
connection.
NOTE: The only Monogram approved plastic tubing is
supplied in the SmartConnect
Refrigerator Tubing kits.
Do not use any other plastic water supply line because
the line is under pressure at all times. Other types of
plastic may crack or rupture with age and cause water
damage to your home.
SmartConnect
Refrigerator Tubing Kits are available
in the following lengths:
2 (.6 m) WX08X10002
8 (2.4 m) WX08X10006
15’ (4.6 m) WX08X10015
25’ (7.6 m) WX08X10025
Shut off the main water supply.
Turn on the nearest faucet long enough to clear the
line of water.
Install a shut-off valve between the icemaker water
valve and cold water pipe in a basement or cabinet.
The shut-off valve should be located where it will be
easily accessible.
Turn on the main water supply and flush debris.
Run about a quart of water through the tubing into a
bucket. Shut off the water supply at the shut-off valve.
NOTE: Saddle type shut-off valves are included in
many water supply kits. Before purchasing, make sure
a saddle type valve complies with your local plumbing
codes.
Floor
Cold Water Line
NOTE: Commonwealth of Massachusetts Plumbing
Codes 248CMR shall be adhered to. Saddle valves
are illegal and use is not permitted in Massachusetts.
Consult with your licensed plumber.
STEP 6 INSTALL CASE TRIM
The unit arrives with case trim for standard installation
attached. Flush installation case trim is provided.
Remove the three pieces of factory installed case
trim (both sides and top). Install new case trim using
supplied right hand and left hand case trim pieces
and case trim screws. A top piece of case trim is
not required for flush
installation. Attach case
trim to each side of case
as shown in illustration
using case trim screws
in holes provided down
each side of the case.
31-49171 Rev. 2