Specifications

32
Door swing clearances
All Monogram refrigeration modules are factory set for a 11
door swing.
When installed in a corner:
Allow the minimum door swing clearances shown.
The minimum clearance shown at 90° will allow full extension
of drawers and shelves.
Location requirements
All Monogram refrigeration modules may be closed in on
the top and sides as long as the front is unobstructed for
air circulation and door swing.
The outdoor/indoor refrigerator may be operated in an
environment where the temperatures are 45°F (7°C) to
120°F (49°C).
Do not install where it will be subject to direct sunlight,
heat or moisture.
These products are not designed to be stacked one over
the other.
Electrical
A 120V, 60HZ., 15 or 20 amp power supply is required. An
individual properly grounded branch circuit or circuit breaker
is recommended. Install a properly grounded 3-prong electrical
receptacle recessed into the back wall as shown. This product
must be connected to a power source with Ground Fault Circuit
Interrupter (GFCI) protection when installed in an outdoor
location. Local codes may require a separate circuit.
The serial plate is located on the inside ceiling.
Advance planning for outdoor/indoor refrigerator
The installation space
The Monogram
®
outdoor/indoor refrigerator may be installed
beneath a countertop or can be used free-standing. The top
canopy can be removed for installation below a countertop.
If installing between frameless cabinets, a 1/2"-wide filler
strip or side panel may be required. The filler strip will act as
a spacer between the door case and adjacent cabinet and
will prevent interference with cabinet door swing. The width
of the opening must include filler panels.
34-1/2" Min.
24" Min.
23-3/4"
34-1/4" - 34-3/4"
(36"with top
canopy)
23-3/4"
1-1/2"
Locate Outlet
9"
Max.
10-1/2"
26-1/2"
Including
Handle
23-3/4" Min.
Note: When installed, the door should project forward
1-1/2" of adjacent 24"-deep cabinets.
A
Minimum to Wall
110°
110° Door
Swing
21-5/8"
23-5/8"
B
Minimum to Wall
90°
90° Door
Swing
15"
Minimum to Wall
5-1/4"
Minimum to Wall
Right-hand door swing
shown. Allow the same
clearances for left-hand
models on the opposite side.