Specifications

54
2-7/8“ Min.
from Cutout
to Rear Vertical
Combustibles
19-5/8”
30-3/4”
21”at sides
28-1/2”
30” Min.
Cabinet Base
2-1/2” Min.
from Cutout
to Front of
Countertop
12” Min.
from Cutout
to Side Walls
3-3/4”
21-5/8”at center
3-3/8” Min.
from Cutout
to Rear Vertical
Combustibles
19-1/8”
36-3/4”
20-5/16” at sides
21-3/16” at center
3-3/4”
33-7/8”
36” Min.
Cabinet Base
2-1/2” Min.
from Cutout
to Front of
Countertop
12” Min.
from Cutout
to Side Walls
Advance planning for gas cooktops
36" stainless steel gas cooktop
Stainless steel cooktops are factory set for natural or liquid
propane gas. Be sure to order the correct model for your
installation.
Note: If the wrong fuel type is ordered, the cooktop can be
converted for other fuel operation. Conversion orifices are
packed with each cooktop. They can be installed by a qualified
service technician at additional cost.
WB28T10185 High altitude conversion kit is available for
operation above 5,000 feet. This kit includes orifices for both LP
and natural gas.
Electrical requirements
This cooktop requires a 120V, 60Hz power supply. A separate
circuit, protected by a 15-amp time-delay fuse or circuit
breaker, is required.
Gas supply
• The natural gas model is designed to operate at 5" water
column pressure. A regulator is required at the natural gas
source to provide a maximum of 14" water pressure to the
cooktop regulator.
The liquid propane model is designed to operate at 11" water
column pressure. A regulator is required at the LP source to provide
a maximum of 14" water pressure to the cooktop regulator.
Combination installations
Consideration must be given to gas and electrical supply
locations when the cooktop is installed with other products in
the same cabinet. Always refer to each product’s installation
instructions for clearances and electrical requirements.
• Install these cooktops with any 36" or wider exhaust hood with
350 CFM or greater air flow rating.
• This cooktop may be installed above a Monogram single oven.
• This cooktop may be installed in combination with a
Monogram
®
36" downdraft vent or above a Monogram 30"
warming drawer. See downdraft vents and warming drawers
for details.
30" stainless steel gas cooktop
Stainless steel cooktops are factory set for natural or liquid
propane gas. Be sure to order the correct model for your
installation.
Note: If the wrong fuel type is ordered, the cooktop can be
converted for other fuel operation. Conversion orifices are
packed with each cooktop. They can be installed by a qualified
service technician at additional cost.
WB28T10185 High altitude conversion kit is available for
operation above 5,000 feet. This kit includes orifices for both LP
and natural gas.
Electrical requirements
This cooktop requires a 120V, 60Hz power supply. A separate
circuit, protected by a 15-amp time-delay fuse or circuit
breaker, is required.
Gas supply
• The natural gas model is designed to operate at 5" water
column pressure. A regulator is required at the natural gas
source to provide a maximum of 14" water pressure to the
cooktop regulator.
The liquid propane model is designed to operate at 11" water
column pressure. A regulator is required at the LP source to provide
a maximum of 14" water pressure to the cooktop regulator.
Combination installations
Consideration must be given to gas and electrical supply
locations when the cooktop is installed with other products in
the same cabinet. Always refer to each product's installation
instructions for clearances and electrical requirements.
• Install these cooktops with any 30" or wider exhaust hood
with 350 CFM or greater air flow rating.
• This cooktop may be installed in combination with a
Monogram downdraft vent. See downdraft vents for details.
• This cooktop may be installed above a Monogram
warming drawer. See warming drawers for details.
• This cooktop may be installed above a Monogram single oven.
The serial plate is located on the bottom of the cooktops.
ZGU385NSMSS natural gas
ZGU385LSMSS LP gas
ZGU384NSMSS natural gas
ZGU384LSMSS LP gas
Locate the gas and electrical supply
as shown. The gas inlet is located on
the bottom of the burner box, 2" from
the right side and 1-1/2" from the rear.
See installation instructions for details.
Locate gas and electrical supply
as shown. The gas inlet is located
on the bottom of the burner box, at
the center and 2" from the rear. See
installation instructions for details.