Specifications

monogram.com
59
Profes sional ga s c ooktop s
Gas coo kt opsIndu ction cookt ops
21-1/4" SS
21-1/8" B/W
Deep at
Center
1-3/4"
Min.
*3-1/4"
36-1/8" SS
36" B/W
33-7/8"
2-1/2"
Min.
to
Front
Edge
19-1/8"
2" Min.
to Side Walls
605Dia128
Electrical requirements
Product rating is 120/208 or 120/240V, 60Hz. For 240V, connect
to a 50-amp circuit; connect to a 40-amp circuit for 208V
operation. The cooktop must be connected to a supply circuit
of the proper voltage and frequency and protected by a time-
delay fuse or circuit breaker.
ZEU36KSKSS Solid black with stainless steel trim
ZEU36KWKWW Solid white
ZEU36KBKBB Solid black
Combination installations
Consideration must be given to electrical supply locations when
the cooktop is installed with other products in the same cabinet.
Always refer to each product’s installation instructions for
clearances and electrical requirements.
Install these cooktops with any exhaust hood of the same
or greater width; 300 CFM or greater air flow rating is
recommended.
The cooktop may be installed with a 36" Monogram downdraft
vent. See downdraft vents for details.
* 3-1/4" deep at the front.
4-5/8" deep at the rear conduit
location. Requires 5" minimum
clearance below the cooktop
bottom to combustible materials.
16" Min
Junction
Box
605Dia125
605Dia126
3-1/4"
6-1/4"
5-1/2"
16" Min
Junction
Box
605Dia125
ZEU30RSFSS Black with
stainless steel trim
ZEU30RBFBB Black
30" digital cooktop (in inches)
A B (at center)
ZEU30RSFSS 29-7/8" 21-5/8"
ZEU30RBFBB 29-3/4" 21-1/2"
Electrical requirements
Product rating is 120/208 or 120/240V, 60Hz. For 240V,
connect to a 40-amp circuit; connect to a 30-amp circuit for
208V operation. The cooktops must be connected to a
supply circuit of the proper voltage and frequency and
protected by a time-delay fuse or circuit breaker.
Combination installations
Consideration must be given to electrical supply locations when
the cooktop is installed with other products in the same cabinet.
Always refer to each product’s installation instructions for
clearances and electrical requirements.
Install these cooktops with any exhaust hood of the same or
greater width; 300 CFM or greater air flow rating is recommended.
The 30" cooktop may be installed in combination with a
Monogram 30" downdraft vent. Install the 36" cooktop with
a 36" downdraft vent. See downdraft vents for details.
A 27" warming drawer may be installed beneath a 30" digital
cooktop, and a 30" warming drawer may be installed beneath
a 36" digital cooktop.
A Monogram single oven may be installed below these cooktops.
The serial plate is located on the bottom of the cooktops.
All models require 5" minimum
clearance below the cooktop bottom
to combustible materials.
Advance planning for electric cooktops
605Dia124
A
28-1/2"
2" Min.
to Side Walls
B
2-1/2" Min.
to Front Edge
1-3/4"
Min.
19-5/8"
ZEU36RSFSS Black with
stainless steel trim
ZEU36RBFBB Black
36" digital cooktop (in inches)
A B (at center)
ZEU36RSFSS 36-1/8" 21-1/4"
ZEU36RBFBB 36" 21-1/8"
605Dia123
A
33-7/8"
2" Min.
to Side Walls
B
2-1/2" Min.
to Front Edge
1-3/4"
Min.
19-1/8"
Elec tric cookt ops