Specifications

monogram.com
65
Chi mne y h oo ds
Pro fes sio nal ho od sCu sto m hoo d inse r t sTel esc opic
do wndr af t ve nts
Advance planning for chimney hoodswall-mount
Product dimensions and clearances
This vent hood can be installed for vented or recirculating
operation. It can be installed over any Monogram cooktop
(except Professional models).
ZV800SJSS, Stainless steel
ZV800BJBB, Black
Telescoping duct covers
are provided to reach
8 ft. to 10 ft. ceiling
heights.
The canopy extends
forward 5-7/8".
Determine installation height
Use this chart to accurately determine installation heights,
depending on your ceiling heights.
Wall-mount ZV800 installation heights
Actual ceiling Possible vented Possible recirculating
height installation height* installation
7' 11" 24" to 27" 24" to 25"
8' 0" 24" to 28" 24" to 26"
8' 1" 24" to 30" 24" to 27"
8' 2" 24" to 30" 24" to 28"
8' 3" 24" to 30" 24" to 29"
8' 4" 24" to 30" 24" to 30"
8' 5" 24" to 30" 24" to 30"
8' 6" 24" to 30" 24" to 30"
8' 7" 24" to 30" 24" to 30"
8' 8" 24" to 30" 24" to 30"
8' 9" 24" to 30" 24" to 30"
8' 10" 24" to 30" 24" to 30"
8' 11" 24" to 30" 24" to 30"
9' 0" 24" to 30" 24" to 30"
9' 1" 24" to 30" 24" to 30"
9' 2" 24" to 30" 24" to 30"
9' 3" 24" to 30" 24" to 30"
9' 4" 24" to 30" 24" to 30"
9' 5" 24" to 30" 24" to 30"
9' 6" 24" to 30" 24" to 30"
9' 7" 25" to 30" 24" to 30"
9' 8" 26" to 30" 24" to 30"
9' 9" 27" to 30" 24" to 30"
9' 10" 28" to 30" 24" to 30"
9' 11" 29" to 30" 25" to 30"
10' 0" 30" 26" to 30"
*Based on 36" countertop height.
Venting and recirculating
wall-mount installations
The vent hood must be
installed 24" min. to 30"
max. above the standard
36" countertop. The hood
installation height, from
the cooking surface to the
bottom of the hood, depends
on the ceiling height.
Vented or recirculating
installations in a cabinet
The vent hood height must
be at least 24" min. above
the standard 36" countertop.
• In both vented and
recirculating installations,
the cabinet must measure
at least 20" from the bottom
frame to the inside top.
• The cabinet must be at
least 12" deep. The hood
housing will occupy the
interior cabinet space.
Recirculating installation
• The exhaust must be returned to the kitchen; it cannot exit
inside the cabinet.
• The exhaust can be directed through the soffit or upper
cabinet to a vent opening with a minimum of 28 square
inches or 6" round. A customer-supplied decorative louver
should be installed.
• The exhaust should be directed away from other cabinet
surfaces, either exposed or hidden.
ZV800SJSS and JV800BJBB duct cover dimensions
The serial plate is located behind the removable filters.
Louver at top of cabinet
in this example