Chi mne y h oo ds
Pro fes sio nal ho od sCu sto m hoo d inse r t sTel esc opic
do wndr af t ve nts
Advance planning for chimney hoodsisland
This vent hood must be installed 24" min. to 30" max. above the
cooking surface; 25-1/2" is recommended to
ensure that the
duct cover meets the ceiling. The cooking
surface should be at
least 36" above the floor.
Product dimensions and clearances
This stainless steel hood can be installed over any Monogram
®
cooktop except Professional models. Accessories to meet
correct ceiling heights are required.
Model ZV850SB
* 26-1/4" for 8-ft. ceiling using
ZX858SB accessory
38-1/4" for 9-ft. ceiling using
ZX859SB accessory
50-1/8" for 10-ft. ceiling using
ZX8510SB accessory
605Dia150
*Height
to Ceiling
8-1/4"
35-3/8"
27-1/2"
605Dia151
*25-1/2" Recommended
36" Min.
Using duct cover accessories
A duct cover accessory is required for all ceiling heights.
Use this chart to determine the correct duct cover accessory
for 8-ft. to 10-ft. ceilings that must be ordered with the hood.
ZV850SB installation heights
Actual Possible hood Duct
ceiling installation cover Recirculating
height height* accessory accessory
7' 11" 24-1/2" ZX858SB ZXR858C
8' 0" 25-1/2" ZX858SB ZXR858C
8' 1" 25-1/2" to 26-1/2" ZX859SB ZXR859C
8' 2" 25-1/2" to 27-1/2" ZX859SB ZXR859C
8' 3" 25-1/2" to 28-1/2" ZX859SB ZXR859C
8' 4" 25-1/2" to 29-1/2" ZX859SB ZXR859C
8' 5" 30" ZX859SB ZXR859C
8' 6" 30" ZX859SB ZXR859C
8' 7" 30" ZX859SB ZXR859C
8' 8" 30" ZX859SB ZXR859C
8' 9" 30" ZX859SB ZXR859C
8' 10" 30" ZX859SB ZXR859C
8' 11" 30" ZX859SB ZXR859C
9' 0" 30" ZX859SB ZXR859C
9' 1" 30" ZX8510SB ZXR8510C
9' 2" 30" ZX8510SB ZXR8510C
9' 3" 30" ZX8510SB ZXR8510C
9' 4" 30" ZX8510SB ZXR8510C
9' 5" 30" ZX8510SB ZXR8510C
9' 6" 30" ZX8510SB ZXR8510C
9' 7" 30" ZX8510SB ZXR8510C
9' 8" 30" ZX8510SB ZXR8510C
9' 9" 30" ZX8510SB ZXR8510C
9' 10" 30" ZX8510SB ZXR8510C
9' 11" 30" ZX8510SB ZXR8510C
10' 0" 30" ZX8510SB ZXR8510C
*Based on 36" countertop height.
A
B
15-3/4"
9-7/16"
ZV850 duct cover dimensions
Vented
installation A B
ZV858SB 14-3/16" 15-3/16"
ZX859SB 20-1/2" 22-1/2"
ZX8510SB 26" 27-1/2"
Recirculating
installation A B
ZV858C 14-3/16" 15"
ZX859C 21-7/8" 22-1/2"
ZX8510C 26" 27-15/16"
The serial plate is located behind the removable filters.