Specifications

76
Advance planning for professional hoods
Installation height requirements
Restaurant-style hoods
These vent hoods must be installed 30" min. to 36" max. above
the standard 36”-high cooking surface. When installed with
the warming shelf, allow 32" min. to 38" max. clearance. The
exact hood installation height is determined by the ceiling
height.
1. Measure the exact ceiling height.
2. Review the chart below to determine the range of hood
installation heights that can be accomplished with a 6”
or 12” duct cover accessory.
Increase or decrease hood installation height to
accommodate the fixed 6” or 12” duct cover heights.
Duct covers may be stacked, in various combinations,
to reach ceiling heights.
Note: When determining the installation height, consideration
must be given to the use of the warming shelf.
Using duct cover accessories
One or more duct cover accessories may be required for your
hood installation height. Use this chart to determine the size
and number of duct cover accessories required depending on
the use of the supplied warming shelf.
Restaurant-style hoods Restaurant-style hoods
without warming shelf with warming shelf
installed installed
Possible Possible
Actual hood hood
ceiling installation installation
height height* 6" 12" height* 6" 12"
7' 11" 31" 1 1 37" 1
8' 0" 32" 1 1 32" 1 1
8' 0" 38" 1
8' 1" 33" 1 1 33" 1 1
8' 2" 34" 1 1 34" 1 1
8' 3" 35" 1 1 35" 1 1
8' 4" 30" 2
8' 4" 36" 1 1 36" 1 1
8' 5" 31" 2 37" 1 1
8' 6" 32" 2 32" 2
8' 6" 38" 1 1
8' 7" 33" 2 33" 2
8' 8" 34" 2 34" 2
8' 9" 35" 2 35" 2
8' 10" 30" 1 2
8' 10" 36" 2 36" 2
8' 11" 31" 1 2 37" 2
9' 0" 32" 1 2 32" 1 2
9' 0" 38" 2
9' 1" 33" 1 2 33" 1 2
9' 2" 34" 1 2 34" 1 2
9' 3" 35" 1 2 35" 1 2
9' 4" 30" 3
9' 4" 36" 1 2 36" 1 2
9' 5" 31" 3 37" 1 2
9' 6" 32" 3 32" 3
9' 6" 38" 1 2
9' 7" 33" 3 33" 3
9' 8" 34" 3 34" 3
9' 9" 35" 3 35" 3
9' 10" 30" 1 3
9' 10" 36" 3 36" 3
9' 11" 31" 1 3 37" 3
10' 0" 32" 1 3 32" 1 3
10' 0" 38" 3
*Based on 36" countertop height.
Note: Additional duct covers may be used to reach higher ceilings.
30" Min.
36" Max.
Ceiling
Height
to Floor
Duct Cover(s)
10" Hood
Height
32" Min.
38" Max.
Ceiling
Height
to Floor
Duct Cover(s)
10" Hood
Height
Duct
cover
Duct
cover