Specifications

monogram.com
77
Chi mne y h oo ds
Pro fes sio nal ho od sCu sto m hoo d inse r t sTel esc opic
do wndr af t ve nts
Advance planning for professional hoods
Installation height requirements
Tapered- and straight-sided hoods
These vent hoods must be installed 30" min. to 36" max.
above the standard 36"-high cooking surface. The exact
hood installation height is determined by the ceiling height.
1. Measure the exact ceiling height.
2. Review the chart at right to determine the range of hood
installation heights that can be accomplished with a 6" or
12" duct cover accessory.
Increase or decrease hood installation height to
accommodate the fixed 6" or 12" duct cover heights.
Duct covers may be stacked, in various combinations,
to reach ceiling heights.
Using duct cover accessories
One or more duct cover accessories may be required
for your hood installation height. Use this chart to
determine the size, number or combination of duct cover
accessories required.
Tapered- or
straight-sided Straight-sided
hoods with hoods only
standard with full-width
duct cover duct cover
Actual Possible hood
ceiling installation
height height* 6" 12" 6" 12"
7' 11" 35" 1 1
8' 0" 30" 1 1
8' 0" 36" 1 1
8' 1" 31" 1 1
8' 2" 32" 1 1
8' 3" 33" 1 1
8' 4" 34" 1 1
8' 5" 35" 1 1
8' 6" 30" 1 1 1 1
8' 6" 36" 1 1
8' 7" 31" 1 1 1 1
8' 8" 32" 1 1 1 1
8' 9" 33" 1 1 1 1
8' 10" 34" 1 1 1 1
8' 11" 35" 1 1 1 1
9' 0" 30" 2 2
9' 0" 36" 1 1 1 1
9' 1" 31" 2 2
9' 2" 32" 2 2
9' 3" 33" 2 2
9' 4" 34" 2 2
9' 5" 35" 2 2
9' 6" 30" 1 2 1 2
9' 6" 36" 2 2
9' 7" 31" 1 2 1 2
9' 8" 32" 1 2 1 2
9' 9" 33" 1 2 1 2
9' 10" 34" 1 2 1 2
9' 11" 35" 1 2 1 2
10' 0" 30" 3 3
10' 0" 36" 1 2 1 2
10' 1" 31" 3 3
10' 2" 32" 3 3
10' 3" 33" 3 3
10' 4" 34" 3 3
*Based on 36" countertop height.
Note: Additional duct covers may be used to reach higher ceilings.
Installation Height
Ceiling Height
to Floor
Duct Covers
18" Hood
Height
Duct
cover
Duct
cover
The serial plate is located behind the removable filters.