Specifications

78
Advance planning for professional island hoods
Installation height requirements
These vent hoods must be installed 30" min. to 36" max.
above the standard 36"-high cooking surface. The exact
hood installation height is determined by the ceiling height.
1. Measure the exact ceiling height.
2. Review the chart at right to determine the range of hood
installation heights that can be accomplished with or
without an accessory kit.
Accessory support frames with duct covers
ZX42DC10—Optional accessory for ZV42I, for use with ceiling
heights of 8' 6" to 10' 4". Kit includes telescoping support
frames and duct covers.
ZX54DC10—Optional accessory for ZV54I, for use with ceiling
heights of 8' 6" to 10' 4". Kit includes telescoping support
frames and duct covers.
Using duct cover accessories
A duct cover accessory may be required for your hood
installation height. Use this chart to accurately determine
the need for a duct cover accessory.
30" Min. and 36" Max.
36"
to
Countertop
Duct Cover
20" for ZV42I
24" for ZV54I
Ceiling
Height
Installation heights Installation heights
ZV42 ZV54
Possible Possible
Actual hood Duct hood Duct
ceiling installation cover installation cover
height height* access. height* access.
7' 11" 30" Supplied 30" Supplied
8' 0" 31" Supplied 31" Supplied
8' 1" 32" Supplied 32" Supplied
8' 2" 33" Supplied 33" Supplied
8' 3" 34" Supplied 34" Supplied
8' 4" 35" Supplied 35" Supplied
8' 5" 36" Supplied 36" Supplied
8' 6" 30" to 31" ZX42DC10 30" ZX54DC10
8' 7" 30" to 32" ZX42DC10 30" to 31" ZX54DC10
8' 8" 30" to 33" ZX42DC10 30" to 32" ZX54DC10
8' 9" 30" to 34" ZX42DC10 30" to 33" ZX54DC10
8' 10" 30" to 35" ZX42DC10 30" to 34" ZX54DC10
8' 11" 30" to 36" ZX42DC10 30" to 35" ZX54DC10
9' 0" 30" to 36" ZX42DC10 30" to 36" ZX54DC10
9' 1" 30" to 36" ZX42DC10 30" to 31" ZX54DC10
9' 2" 30" to 36" ZX42DC10 30" to 32" ZX54DC10
9' 3" 30" to 36" ZX42DC10 30" to 33" ZX54DC10
9' 4" 30" to 36" ZX42DC10 30" to 34" ZX54DC10
9' 5" 30" to 36" ZX42DC10 30" to 35" ZX54DC10
9' 6" 30" to 36" ZX42DC10 30" to 36" ZX54DC10
9' 7" 30" to 36" ZX42DC10 30" to 36" ZX54DC10
9' 8" 30" to 36" ZX42DC10 30" to 36" ZX54DC10
9' 9" 30" to 36" ZX42DC10 30" to 36" ZX54DC10
9' 10" 30" to 36" ZX42DC10 30" to 36" ZX54DC10
9' 11" 30" to 36" ZX42DC10 31" to 36" ZX54DC10
10' 0" 30" to 36" ZX42DC10 32" to 36" ZX54DC10
10' 1" 30" to 36" ZX42DC10 33" to 36" ZX54DC10
10' 2" 30" to 36" ZX42DC10 34" to 36" ZX54DC10
10' 3" 31" to 36" ZX42DC10 35" to 36" ZX54DC10
10' 4" 32" to 36" ZX42DC10 36" ZX54DC10
*Based on 36" countertop height.
The serial plate is located behind the removable filters.