Specifications

Chi mne y h oo ds
Pro fes sio nal ho od sCu sto m hoo d inse r t sTel esc opic
do wndr af t ve nts
monogram.com
83
Creative solutions
Against-the-wall installation
Move the base cabinet forward, 3" to 5". Filler panels or
complimentary moldings can be added to the exposed
cabinet sides.
Optional accessories
JXRB67 Accessory for indoor remote location of the blower/
motor assembly. Use this kit when the blower and motor
assembly will be located outside of the cabinet, such as below
the cabinet floor. The assembly will fit between 16" floor joists.
JXBC67 Outdoor cover accessory for remote installation of the
blower/motor assembly on an outside wall.
Duc twork
Prepare the ductwork to vent to the outdoors.
Plan the shortest and straightest route for venting exhaust
to the outdoors.
The maximum permissible length for the duct run is 150 feet.
Use metal ductwork only.
The downdraft blower system is designed to use 3-1/4" x 10"
duct. It can be transitioned to 6" round.
Install a wall cap or roof cap with damper at the exterior
opening.
Order the wall cap and any transition needed
in advance.
Venting options
The downdraft vent is shipped with the discharge outlet
pointing straight down and can be changed to a left- or right-
side discharge. For even more flexibility, the entire blower and
mounting plate can be adjusted 3-1/2" to the left or right sides.
605Dia159
Base Cabinet
Filler Panel
Base Sink
Filler Panel
Maintain Cutout Clearances
to Front Edge as Specified
Island or peninsula installation
Use an extra-deep countertop. The countertop overhang at the
front can be adjusted to meet setback to cutout requirements.
605Dia160
Cover Panel
Base Sink
End
Panel
Countertop Overhang per Cooktop
Clearances Must be Maintained
Decorative trim
When the cutout to front edge of the countertop
requirement is more than 2", add a bullnose trim to the
front edge of the countertop. The additional trim allows
the cooktop to be moved forward, providing additional
countertop depth and interior cabinet space.
605Dia161
DOWNDRAFT
VENT
1-7/8"
Trim
Add a Bullnose
Trim or Decorative
Molding to
Increase
Countertop
Depth and to
Maintain
Required
Clearance From
Front Edge
682Dia49
Discharge Down
(As Supplied)
682Dia50
Discharge Left
682Dia51
Discharge Right
Advance planning for telescopic downdraft vents