Owner’s Guide and Installation Manual Downrod with light kit Flush Mount -Light kit Downrod without light kit Flush Mount -No light kit 5AN52XXD-L Series Fan UL Model No. : 14105 Attach sales receipt to this card and retain as your proof of purchase DATE OF PURCHASE: RETAILER NAME: MODEL NUMBER: RETAILER ADDRESS: To register your fixture, please visit our website www.montecarlofans.com 10.6 kgs 23.
WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING READ AND SAVE THESE INSTRUCTIONS Installation work and electrical wiring must be done by qualified person(s) in accordance with applicable codes and standards (ANSI/NFPA 70-1999), including fire-rated construction. Use this unit only in the manner intended by the manufacturer. If you have any questions contact the manufacturer.
1 2 3 For Flush mount with or without the light kit, go to step 4. Before you begin installing the fan, Switch power off at Service panel and lock service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel. Before installing this fan make sure the outlet box is properly installed to the house structure.
10 11 12 Lift the motor bracket so that the threaded studs on the mounting plate protrude through the slots in the motor bracket. Securely tighten the locknuts onto the threaded studs. Loosen the two screws and washers on the cross on the top of the mounting plate. Remove the other two screws and lock washers and save for later use.. Lift housing up aligning the L shape holes with the screws on the mounting plate. Turn housing clockwise to hold in position.
18 Remove the cardboard from fitter. 21 19 20 Tighten the hex nut and lock washer to the switch cap. NOTE: Make sure the slot in the switch cap is facing the socket as shown so that the chain can be pulled smoothly. (As shown in inset) Connect the white wire from the fitter to the white wire from the switch cap. Connect the black wire from the fitter to the blue wire from the switch cap. 22 23 Install 3x40 watt candelabra bulbs. Bulbs are not included.
27 28 29 Remove the hex nut and lock washer from the switch cap. Remove the switch cap from the fitter. Insert the center plastic plug provided into the center hole of the switch cap. 30 31 32 Install switch cap onto fan using 3 screws removed from step 17 and tighten securely. 33 Remove the cotter and keeper pins and save for later use. © 2013 Monte Carlo Fan Company Use metal outlet box suitable for fan support and use only the screws provided with the outlet box (must support 35 lbs).
36 37 38 Thread leadwires and safety cable through the motor housing cover, the canopy, and downrod. Insert downrod into yoke. Align the hole in the downrod with hole in the yoke. Insert the pin through the yoke and downrod until the point appears on the other side. 39 40 41 Install the keeper to pin. Tighten the 2 set screws on the yoke once the downrod is in place. Hang assembled fan to the mounting bracket installed to ceiling in previous step.
45 Make wire connections to power source using wire nuts provided. Make sure that no filiments are outside of the wirenut. After making the wire connections, the wires should be spread apart with the grounded conductor and the equipment-grounding conductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box. 48 Lift housing up aligning the L shape holes with the screws on the mounting plate. Turn housing clockwise to hold in position.
TROUBLe SHOOTING If you have difficulty operating your new ceiling fan, it may be the result of incorrect assembly, installation, or wiring. In some cases, these installation errors may be mistaken for defects. If you experience any faults, please check this Trouble Shooting Chart. If a problem cannot be remedied, or you are experiencing difficulty in installation, please call our Customer Service Center at the number printed on your parts list insert sheet.
Apr.2012 New format Jun.2013 Update for CUL regulation Aug.9.