Installation & Assembly

Page 1
MANUFACTURER ,167$//$7,21 GUIDELINES
/8;85<9,1</7,/(/97,167$//$7,21*8,'(/,1(6
This manufacturer features the patented Unilin® interlocking planks for easy installation and is installed as a glueless floating floor. The interlocking
planks lock together to provide a tight water resistant seam, can be installed over most floor surfaces, and is suitable for both residential and light
commercial interior applications.
Introduction:
This LVT collection features the patented Uniclic® glueless floating installation system from Unilin®. The interlocking planks easily lock together to
provide a tight water resistant seam, can be installed over most floor surfaces, and are suitable for both residential and light commercial interior
applications.
General Information
 Flooring should be transported and stored in a neatly stacked fashion on a smooth flat surface.
 Acclimate the flooring and the rooms to be installed at a constant temperature between 65°F and 85°F for 48 hours before, during, andmaintained
after installation.
 This flooring should only be installed after other trades have finished and the jobsite has been cleaned and cleared of debris that couldpotentially
damage a finished plank installation.
 Inspect flooring for damage, defect, or shading issues before installation; claims for visual defects will not be accepted after cutting and or/installed.
 Mix and install planks from several different cartons during installation to ensure a random appearance.
 Leave 1/4 inch (6.35mm) for expansion around the entire perimeter of the flooring.
 Flooring should be protected from direct exposure to sunlight.
 The maximum area of installation for Luxury Vinyl Plank/Tile without transition strips is 25ft Wide X 30ft Long. Once these dimensions havebeen
exceeded appropriate transition strips will need to be used.
Subfloors:
Planks can be installed over a variety of subfloor surfaces including concrete on all grade levels, wood and many existing hard surface floors. The
subfloors must be clean, smooth, flat, solid (no movement), and dry. Do not install planks over floors that are sloped for drainage. Any uneven areas
greater than 3/16 inch (4.76mm) in a 10 foot (3.05m) radius should be leveled with a Portland cement based patching compound. This product is
resistant to water damage but they do not prevent the transmission of moisture. Care should be taken to keep moisture from collecting on either side
of the flooring to prevent the growth of unhealthy mold and mildew.
Concrete Subfloors:
Planks can be installed over concrete on all grade levels if a proper moisture barrier is used. A minimum 6 mil polyethylene moisture barrier must be
used with concrete subfloors. Moisture vapor emissions should not exceed 5 lbs./24 hour per 1,000 sq. when tested with the Anhydrous Calcium
Chloride Test in accordance with ASTM F 1869 or 80% RH in accordance with ASTM F 2170 “Standard Test Method for Determining Relative Humidity
in Concrete Slabs using in situ Probes. Any uneven areas greater than 3/16 inch (4.76mm) in a 10 foot (3.05m) radius should be leveled with a
Portland cement based patching compound. Holes and cracks in the cement should be patched, and expansion joints should be filled with a latex
patching compound. Newly poured concrete floors must cure for a minimum of 90 days. Please note it is the person installing the floor and/or the
homeowner’s responsibility to ensure any moisture or alkalinity issues are resolved prior to installing the floor
127(([FHVVLYHPRLVWXUHPD\FDXVHWKHJURZWKRIXQKHDOWK\PROGRUPLOGHZDQGRUFDXVHVWDLQLQJRIWKHIORRULQJZKLFKLVQRWFRYHUHGE\RXU
:DUUDQW\

Summary of content (4 pages)