USING SUBHARMONICON AS A EURORACK MODULE
Your Subharmonicon can be removed from its case and easily installed into a Eurorack system as a
60HP module. Before doing this, it is important to note that Subharmonicon draws a maximum of
360mA from a +12V rail. It does not use the -12V rail at all. Make sure there is enough headroom on the
+12V rail in your system to power the Subharmonicon.
NOTE: You will need to know the current rating of the system’s +12VDC rail and the current draw of
the +12VDC rail from all modules in the system combined. The sum of all current draw at +12VDC should
never exceed the power supply rating. Note that it is good practice to leave some headroom to reduce stress
on the power supply.
Moog accepts NO responsibility or liability for improperly installed modules.
TO INSTALL THE SUBHARMONICON IN A EURORACK SYSTEM
1. Disconnect external power from the unit.
2. Remove the eight black M3 screws on the front panel and keep them somewhere safe. You will need
them again.
3. Slowly lift the panel from the case, so that you can see the two cables going to the front panel module.
4. Disconnect these two cables from the front panel. The module is now free from its enclosure.
5. Look at the back of your Subharmonicon
module. There is a 10-pin power header on
the back of the PCB that accepts a 10-pin
Eurorack power ribbon cable (not included).
6. Connect PIN-1 (-12V) of the power ribbon
cable to PIN-1 of the Subharmonicon
Eurorack power header. The darkened wire
(typically red) on the ribbon cable indicates
the PIN-1 (-12V) side of the cable.
7. After power is connected, your
Subharmonicon may be installed into the
rails of the Eurorack system case with the
eight black M3 screws removed in Step 2.
8. Once fully installed, you may power up
your Eurorack system.