Operating instructions

OUTPUT: (24VAC
84VA)
CAMERA
and
HEATERS
75 WATTS
MAX
Internal resettable fuses are supplied for the main 24VAC output lines. Do not connect heaters
to camera output. The PB24 is not designed for 3 phase or 208V systems.
24Vac Power
To Housing
Optional 24Vac
Output
Main
Switch
Housing Power
(Connected at Factory)
14
Connect RJ45 network lines
Wiring chart for ALARM and AUDIO options- Inside
power box. Make the necessary connections.
AUDIO
1
2
3
SPEAKER (+)
AUDIO GND
MIC (+)
GRAY
BROWN
WHITE
ALARM
1
2
3
ALARM (IN)
ALARM (OUT)
ALARM (IN / OUT)
BLUE
BLACK / WHITE
VIOLET
4 ALARM (OUT) RED / WHITE
15
16